  • Page 1 KNX Touch One Style Item number 70197 Installation and Ad justment...
  • Page 3: Table Of Contents

    4.2.3. Universal Menu ....................49 Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany Room Controller KNX Touch One Style • from software version 3.0, ETS program version 3.0 Status: 06.03.2017 • Subject to technical changes. Errors excepted.
  • Page 4 5.3. Light applications ................79 Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany Room Controller KNX Touch One Style • from software version 3.0, ETS program version 3.0 Status: 06.03.2017 • Subject to technical changes. Errors excepted.
  • Page 5 6.2. Settings data .................. 144 Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany Room Controller KNX Touch One Style • from software version 3.0, ETS program version 3.0 Status: 06.03.2017 • Subject to technical changes. Errors excepted.
  • Page 6 Explanantion of symbols Explanation of the symbols used in this manual Danger of death by electrocution! Advice on dangers concerning work on electrical terminals, components etc. Safety measures to protect the life and health of relevant personnel. Safety instruction! Instructions that must strictly be observed to ensure the safe operation. Safety measures to protect against damage to persons or property.
  • Page 7: Description

    Description 1. Description Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 8: Field Of Application

    Accessories (not included in the scope of delivery): • Radio remote control Remo 8 1.1.2. Technical Data Housing Glass, plastic Colour White/grey Assembly Flush/cavity wall Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 9 Please also take note that the displayed temperature value will be too high temporarily after a power breakdown. The product conforms with the provisions of EU directives. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 10: Maintenance And Care

    General instructions: • The entire runtime is completed for timed closures • The movement positions are only settable in the blind and ventilation functions Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 11 Wind alarm: Retract when a selectable wind speed is exceeded (can be switched off) • Rain alarm: Retract during rainfall (can be switched off) • Travel position can be set Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 12 • Leave closed during a settable period • Travel position/number of steps (Stepped window openings operate gradually with a selectable number of steps (2-10)) Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 13: Overview Of Functions

    Teaching radio remote control Remo 8 • Programming button/Programming LED (phys. address) • Reset 1.3.2.3. Using ETS and display operable functions Settings • Language • Date and time Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 14: List Of Communication Objects

    Internal temperature meas- Output R-CT [9.1] DPT_- 2 bytes urement value Value_Temp Output R-CT [9.1] DPT_- 2 bytes Overall temperature meas- urement value Value_Temp Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 15 -WCT [9.4] DPT_- 2 bytes Value_Lux Display page selection Input -WC- [5.10] DPT_- 1 Byte Value_1_Ucount Alarm 1 Input -WC- [1.1] DPT_Switch 1 bit Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 16 Start menu function 6 Output R-CT Dep. on setting (Short-term input) Universal menu page 1 Input RWCT Dep. on setting Function 1 (Display / Input) Output Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 17 Dep. on setting Universal menu page Func- tion 141- Dep. on setting Universal menu page Func- tion 157- Dep. on setting Universal menu page Func- tion Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 18 = 1 | Manual = 0) Output Switch Light 6 on/off Output R-CT [1.1] DPT_Switch 1 bit Dim Light 6 Output R-CT [3.7] DPT_Cont- 4 bit rol_Dimming Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 19 = 1 | Manual = 0) Output Blind 3 Extended Output R-CT [1.8] DPT_Up- 1 bit Down Blind 3 Brief Output R-CT [1.10] DPT_Start 1 bit Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 20 = 1 | Manual = 0) Output Awning 1 Extended Output R-CT [1.8] DPT_Up- 1 bit Down Awning 1 Brief Output R-CT [1.10] DPT_Start 1 bit Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 21 = 1 | Manual = 0) Output Roller shutter 2 Extended Output R-CT [1.8] DPT_Up- 1 bit Down Roller shutter 2 Brief Output R-CT [1.10] DPT_Start 1 bit Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 22 2 change (Auto- Input RWCT [1.1] DPT_Switch 1 bit matic = 1 | Manual = 0) Output Fan status Output R-CT [1.1] DPT_Switch 1 bit Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 23 Temp. controller: Setpoint, Input -WC- [1.2] DPT_Bool 1 bit night-time cooling (1:+ | 0:-) Temp. controller: Output R-CT [1.2] DPT_Bool 1 bit Status – Heating 1 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 24 Dep. on setting Scene object 1 Output Scene object 2 Input -WCT Dep. on setting Output Scene object 3 Input -WCT Dep. on setting Output Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 25 [1.8] DPT_Up- 1 bit Down Button 2 Brief Output R-CT [1.10] DPT_Start 1 bit Button 2 switching Input RWCT [1.1] DPT_Switch 1 bit Output Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 26 Actuating variable compara- Input -WC- [1.2] DPT_Bool 1 bit tor 1: Block Actuating variable compara- Input -WC- [5.1] DPT_Scaling 1 Byte tor 2: Input 1 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 27 Input -WC- [1.2] DPT_Bool 1 bit Logic input 1 Input -WC- [1.2] DPT_Bool 1 bit Logic input 2 Input -WC- [1.2] DPT_Bool 1 bit Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 28 AND Logic 4: 8 bit Output B Output R-CT [5.10] DPT_- 1 Byte Value_1_Ucount AND Logic 4: Blocking Input -WC- [1.2] DPT_Bool 1 bit Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 29 1 bit Computer 2: Input I1 Input RWCT Dep. on setting 4 bytes Computer 2: Input I2 Input RWCT Dep. on setting 4 bytes Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 30 1 bit Computer 6: Input I1 Input RWCT Dep. on setting 4 bytes Computer 6: Input I2 Input RWCT Dep. on setting 4 bytes Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 31 14 by- _ASCII Computer 8: Monitoring Output R-CT [1.1] DPT_Switch 1 bit status Computer 8: Block (1: block) Input -WC- [1.1] DPT_Switch 1 bit Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 32 Description Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 33: Installation

    Installation 2. Installation Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 34: Installation

    • Direct sunlight • Drafts from windows and doors • Draft from ducts which lead from other rooms to the concealed box Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 35: Preparing For Installation

    Place the concealed box in the wall so that the arrows point upwards. 2.1.3.1. Wall-fitting For fitting, screw the cover (board) on to the concealed box with the en- closed screws. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 36: Cavity Wall Fitting

    Connect the cables to the display and place the display unit on the concealed box. The magnets must be attracted by the mounting screws considerably and the display unit must rest tightly on the concealed box. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 37 VCC (Auxiliary voltage AC/DC) Terminal 5, 6: Button interface 3 Terminal 5: KNX + Terminal 7, 8: Button interface 4 Terminal 6: KNX - Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 38 Installation Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 39: Initial Start-Up

    Initial start-up 3. Initial start-up Room Controller KNX Touch One • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 40: First Commissioning

    Initial start-up 3.1. First commissioning Installation, inspection, commissioning and troubleshooting of the device must only be carried out by a competent electrician. 3.1.1. Boot the control system Bringing a device from a cold room into a warm room can cause a build-up of condensation.
  • Page 41: Alarm And Error Messages

    Initial start-up 3.2. Alarm and error messages Alarm messages are always prioritised before error messages. When an alarm has already been triggered and displayed on the start screen, error messages are no longer visible. 3.2.1. Warning messages In case of an alarm message from the bus, the display switches to start menu and shows the message.
  • Page 42: Power Failure, Maintenance Work, Etc. (Restart Of Control System)

    Initial start-up • if a failure has led to a loss of connection between the bus and the unit • if the power to the bus fails. Error messages in the drive/light menu: Those messages are displayed next to the drive or light (menu drive/light): Position unknown...! for a shading element or window indicates that the relevant actuator has not sent in- formation about position.
  • Page 43 Initial start-up Resumption of the auxiliary power supply: The following objects are sent: • No. 1 Software version • No. 2 Unit malfunction • No. 10 TH sensor malfunction The following objects send a read telegram: • No. 3 Date •...
  • Page 44 Initial start-up Room Controller KNX Touch One • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 45: Operation

    Operation 4. Operation Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 46: The Touch Screen

    These values are not retained when the unit is reset. The weather data must then be received again from the bus. 4.2.1. Start Screen/Start Menu Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 47 (sources of interference like direct sunlight), they can be corrected manually.  TH sensor, page 73 You get to the Start Menu from all menus by pressing “Home“ Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 48: Weather Data Display

    From the Start Menu, you get to the weather data display by pressing “Weather Display“ The weather data display is a graphical menu for weather and indoor data, date and time. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 49 Air humidity in %RH The general weather situation is shown graphically: Sunny or cloudy: The sun moves across the sky according to its current direction and height. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 50 Start Menu. Comments about alarm and error messages can be found in the chapter  Alarm and error messages, page 39 To Start Menu (“Home“) Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 51: Universal Menu

    Maintained for longer than Time 1 ==> Up/Down Triggered between Times 1 and 1 + 2 ==> Stop Triggered after Times 1 + 2 ==> No further stop Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 52: Adjustment And Operation - Further Options

    Arrow buttons to increase/reduce a value or to scroll through a list of input possibilities. Extended pressing of a button accelerates its input. Up/Down buttons for manual operation Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 53: Input Keyboard For Names And Codes

    &  Delete. Deletes the preceding characters. Shift key. Switches between upper and lower case letters. Moves the cursor/caret one character to the left/right. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 54: Protect Menus With Access Codes

    ETS.  Setting access codes using the ETS, page 77  Setting access codes at the screen, page 78 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 55: Adjustment

    Adjustment 5. Adjustment Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 56: Start Menu

    Display 1 / 0 Display Up (for value 0) / Down (for value 1) Display Up (for value 1) / Down (for value 0) Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 57 0...24 000; 200 For the object function „Input Brief/Extended“, you can trigger the following com- mands by variing the duration of the button press: Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 58 Text input [Start menu only] Text for unit Text input (max. 2 chars.) Value can be set via display Yes • No Start value Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 59: Basic Settings

    You must ensure that the unit can receive weather data at the selected monitoring interval (e.g. every 5 seconds) when wind and rain object monitoring is activated. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 60: Settings Menu At The Screen

    The alarm action is set in the “Alarm“ menu in the ETS (or at the screen).  Alarm, page 76 5.2.2. Settings menu at the screen From the Start Menu, you get to the Settings menu by pressing “Settings“ Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 61: Language

    Activate the Transfer parameter” function for the language in the ETS's General “ “ Settings” menu. Then select the language in the appearing “Language“ menu. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 62: Setting The Language At The Screen

    Start of Summer Time: On the first Sunday After (day) (Month) (Hour) (Minute) End of Summer Time: On the first Sunday After (day) Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 63 End of Summer Time: On the first • Monday ... • Sunday After (day) 1..31; 25 (Month) 1...12; 10 (Hour) 0...23; 2 (Minute) 0...59 Time shift: Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 64: Enter The Date And Time At The Screen

    Press Time zone and then, consecutively, the hour and minute fields in order to set the time zone (relative to GMT) using the arrow buttons. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 65: Location

    7 towns in other countries Location input using Coordinates E. longitude in degrees -180 ... +180; 9 E. longitude in minutes -59 ... + 59; 10 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 66: Setting The Location At The Screen

    • is adjusted to ambient light • controlled by means of an object Brightness in % 1...100 (only when brightness is defined using a set value) Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 67: Setting The Display At The Screen

    11 = Start screen 5.2.6.2. Setting the display at the screen Press the buttons: Display The menu is code-protected if access code 2 is activated. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 68 If the screen is touched, it also re-activates. If no command is given for around 1 minute, the automatic switch-off darkens the screen again. Confirm your setting using the OK button. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 69: Texts

    Scene menu can be changed. Some names for functions can already be set du- ring the setting of the function in the ETS. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 70: Changing Text Using The Ets

    Text field (default setting: Scene 1 - 16) 5.2.7.2. Changing text at the screen Press the buttons: Start menu Texts Universal menu Scene menu Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 71: Automatic Settings

    100...350 (in 0.1 °C) for an extended time which exceeds the 1...72; 48 following hours Frost alarm: No • Yes Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 72: Change Automatic Settings At The Screen

    Press the buttons: Automatic In order to be able to set the automation functions, at least one relevant drive or a light must be configured. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 73 You adjust which blinds will be retracted and which windows will be closed in the au- tomatic functions for the individual blinds and windows. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 74 Automatic reset following a manual intervention: Use the arrow keys to set the time interval after which Automatic functions should be once again activated.Default setting: 60 minutes. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 75: Th Sensor

    • 0,1 • 0,2 • 0,5 • 1,0 • 2,0 • 5,0 Cycle 5 s … 2 h Use minimum / maximum values No • Yes Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 76: Setting The Th Sensor At The Screen

    TH sensor measure- ment value. Pre-setting: 0 % Confirm your setting using the OK button. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 77: Remo 8 Remote Control

    Confirm your selection using OK. Only drives/units with the same function should be controlled together using a single hand-held transmitter channel (for example, blinds or windows alone). Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 78: Alarm

    Make sure that the text you enter is as short and precise as possible. The display alarm text is limited to 15 characters. Confirm your settings by pressing the OK button. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 79: Addressing The Unit

    ETS. Then set the codes in the appearing menu. Access code (for General Settings and for Automatic Settings) Activate access code No • Yes Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 80: Setting Access Codes At The Screen

    If an access code has been activated at the touch display but is no longer available for input, the unit can be unlocked via the ETS Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 81: Reset

    5.3.1. Set light using the ETS Light applications are setup via the menu items “Light 1...8“. Light can be set for sim- ple switching or for dimming. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 82 No • Yes After the input waiting period following No • Yes manual operation  Change general automatic settings using the ETS, page 69 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 83: Operate And Adjust Light At The Screen

    Switch the light using the On or Off buttons. The automatic functions for the respec- tive lighting are deactived by the manual operation (if set so, only to a fixed automatic reset). Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 84 Time switches for up to 16 different time periods • Twilight switching/switching on at night (activatable using time switches) • Dimmer value ON/OFF • Switch automatic reset on/off Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 85 Press the Dimmer value off button in order to set the brightness of the light when it is switched off. Pre-setting: 0%. Adjust the value using the arrow buttons. Confirm your setting using the OK button. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 86: Drives And Ventilation Units

    The automatic control may cause parts of the system to travel and pose a danger to humans. • No persons may remain in the travelling range of parts driven by an electric motor. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 87: Setting Blinds Using The Ets

    Manual direction on the touch menu • Up arrow: Extended 0 | Down arrow: Extended 1 • Up arrow: Extended 1 | Down arrow: Extended 0 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 88 (in °) (only when the selected 0...360; 90 angle range is settable) lower than (in °) (only when the selected 0...360; 270 angle range is settable) Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 89: Setting Awnings Using The Ets

    [Recognition of manual operation] Automatic/Manual object value at • Automatic = 1 | Manual = 0 • Automatic = 0 | Manual = 1 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 90 Shading Always Movement position (in %) 0...100 If shading is used dependent on brightness: Shading Brightness-dependent From a brightness of (in klx) 1...99; 40 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 91: Setting Roller Shutters Using The Ets

    [Recognition of manual operation] Automatic/Manual object value at • Automatic = 1 | Manual = 0 • Automatic = 0 | Manual = 1 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 92  Change general automatic settings using the ETS, page 69 If shading is always used: Shading Always Movement position (in %) 0...100 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 93: Setting Windows Using The Ets

    Use window No • Yes Switch to manual if feedback value No • Yes deviates from automatic nominal value [Recognition of manual operation] Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 94 • Up arrow: Extended 1 | Down arrow: Extended 0 Use TH sensor No • Yes Settings for use of the TH Sensor (indoor temperature/humidity) see bottom. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 95 Close the window when the supply air No • Yes temp. is higher than the room temperature Use night-time cooling for Period 1 - 16 No • Yes Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 96: Setting Ventilation Units Using The Ets

    No • Yes Start ventilation from (in 0.1 °C) 50...500; 250 (only if the interior temperature is used) Use air humidity No • Yes Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 97: Set And Operate Drives At The Screen

    You can operate the drives and ventilation units configured in the ETS directly here: Use the buttons to select the names to the left of the drive or unit which you want to operate. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 98 An automatic reset will switch the device back to automatic mode. The automatic reset can be separately activated for each drive group and each unit in the automatic menu. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 99: Safety Notes For Automatic Functions

    Note that the rails of shutters, awnings and blind which are externally mounted can ice up. Operating the drive under such conditions can damage the shades and drives. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 100: Setting Automatic Functions For Shading Elements

    Press the Name button and input the desired name into the button field which appears.  Input keyboard for names and codes, page 51 Confirm your input using the OK button. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 101 Use shading from a brightness of X kilolux using the arrow buttons and change the value using the arrow buttons depending on your needs. Pre-setting: 40 klx. The drive will always actuate the screen: Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 102 0°” using the arrow buttons which appear. “ “ The thickened section of the image shows the selected area. Confirm your setting using the OK button. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 103 The outdoor temperature block can also be used when no shading should take place in winter. This allows the light and heat of the sun to be utilised fully. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 104 Activate: If the shutter or roller shutter should be closed completely at night, select Yes. Deactivate: If the shutter or roller shutter should remain open at night, select No (de- fault setting). Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 105 This protects external shades from icing and from damage through move- ment when the rails are iced up. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 106 Deactivate: For interior awnings, select No (awnings should not be retracted during rain, default setting). Confirm your setting using the OK button. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 107: Setting Automatic Functions For Windows

    Highest priority is assigned to time closure, followed by the outdoor temperature- block (keep closed), timed ventilation (open), the incoming air temperature-block (keep closed) and night-time re-cooling. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 108 (hysteresis). Shutting off ventilation: If the interior temperature should be independently ventilated, press the Off button. Confirm your setting using the OK button. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 109 No (default setting). Confirm your setting using the OK button. Only for step windows. Number of steps Only when an indoor sensor is selected Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 110 Input the operating position in % using the arrow buttons (0% = closed, 100% = fully open). Pre-setting: 30%. Confirm your setting using the OK button. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 111 Confirm your setting using the OK button. To change any of the time periods set in the timer, press Timer.  Setting the timer at the screen, page 127 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 112 Deactivate: If the security object should not be sent in the event of rain, select No (de- fault setting). Confirm your setting using the OK button. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 113 You can set automatic reset times and/or durations  Settings > Automatic > Automatic Reset  Change automatic settings at the screen, page 70 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 114: Setting Automatic Functions For Ventilation Units

    Setting the temperature: Adjust the value for the desired room temperature using the arrow buttons. Pre-setting: 25.0 °C. Shutting off ventilation: If ventilation is to be independent of indoor temperature, press the button labelled OFF. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 115 Setting maximum ventilation: The ventilator force can be set in 10% steps from 100 to 10% using the arrow buttons (default setting: 100%). Confirm your setting using the OK button. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 116 Press the button to set the ventilation force for timed ventilation. The button will only be activated once a ventilation time for the timed ventilation has been set. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 117: Temperature Control

    • Two-step heating • One-step cooling • One-step heating + One-step cooling • Two-step heating + One-step cooling • Two-step heating + Two-step cooling Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 118 Type of setpoint change • Absolute value • Increase / Decrease Increment (in 0.1 °C) 1 … 50; 10 (only when “increase/reduce” is used) Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 119 Increment (in 0.1 °C) 1 … 50; 10 (only when “increase/reduce” is used) Heating control Set control using • Controller parameter • provided applications Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 120 Upon shut-off, control variable should • not transmitted (do not send: display 0%, • send a specific value Send value: display shows value in %) Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 121 Control variable is a • 1-bit object • 8-bit object Value in % 0 … 100 (only when control variable is an 8-bit object) Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 122 Cooling initial setpoint (in 0.1 °C) -300...800; 300 Object value limit Kmin (in 0.1 °C) -300...800; 240 Object value limit Kmax (in 0.1 °C) -300...800; 360 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 123 Window opening (so that the controller does not immediately heat in the event of short-term temperature variations, e.g. airing) Cooling setpoint in 0.1 °C -300 … 800; 350 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 124: Setting Temperature Control At The Screen

    (heat shield). If a superordinate frost or heat alarm is used, this corresponds to the heating/cooling setpoint temperature. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 125: Universal Menu

    The universal menu must be set up in the ETS.  Universal menu, page 123 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 126: Setting The Universal Menu Using The Ets

    Input + / - Input Up (for value 0) / Down (for value 1) Input Up (for value 1) / Down (for value 0) Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 127 • Display 16-bit floating point • Display 32-bit floating point • Input 16-bit floating point • Input 32-bit floating point Text for unit Text input (max. 2 chars.) Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 128: Universal Menu At The Screen

    For use of the timer, reception of date and time via the bus or manual setting of the internal clock is required. Date and time, page 60 Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 129: Setting The Timer Using The Ets

    Saturday No • Yes Sunday No • Yes 5.7.2. Setting the timer at the screen You can access the timer via the menu: Timer Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 130 The Reset command allows you, at the touch of a button, to reset the time periods to their original condition (start: 00:00, end: 00:00, no weekday). Confirm your setting using the OK button. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 131: Scenes

    (for “8-bit object type in %[0...100]”) Value 0...360 (for “8-bit object type in ° [0...360]”) Value (in 0.1) -6707600...6707600;0 (for “16-bit floating comma object type”) Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 132: Scene Activation At The Screen

    Room Controller KNX Touch One Style. The button inputs are configured in the ETS. Use button interface 1 / 2 / 3 / 4 No • Yes Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 133 If the input to the drive control is used via the bus, select the bus function "shutter", "awning", "blinds" or "window" and specify the button function and control mode. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 134 If briefly operated, the drive will move incrementally or stops. If operated longer, the drive will move up to the end position. The time difference between "short" and "long" is set individually. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 135 Release after time 1 expired but before time 2 expires: Stop Release after time 1 + 2 expired: Move into end position Control mode Comfort mode Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 136: Variable Comparator (Ets)

    (if sent periodically) At and above change of 1% • 2% • 5% • 10% • 20% • 25% • 50% (if sent on change) Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 137: Logic (Ets)

    Each logic output may transmit one 1 bit or two 8 bit objects. Determine what the out put should send if logic = 1 and = 0. Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 138 • on change of logic + receipt of obj.+ periodically Transmission cycle 5 s • 10 s • ... • 2 h (when sending periodically) Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 139: And Logic Connection Inputs

    Logic input 1 inverted Logic input 2 Logic input 2 inverted Logic input 3 Logic input 3 inverted Logic input 4 Logic input 4 inverted Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 140: Connection Inputs Of The Or Logic

    The menus for the further setting of the computer are then displayed. Computer 1/2/3/4/5/6/7/8 No • Yes Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 141: Computer 1-8

    • 4 byte counter with math. symbol • 4 byte floating point Starting value E1 / E2 / E3 [Input range depending on the type of input] Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 142 Send delay in the event of change none • 1 s • ... • 2 h to the condition is not met Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 143 • E3 • E1 and E2 • E1 and E3 • E2 and E3 • E1 and E2 and E3 [depending on the function] Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 144 Output pattern • do not send anything On block • send value On release • as send pattern [see above] • send current value immediately Room Controller KNX Touch One Style • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 145: Tables

    Tables 6. Tables Room Controller KNX Touch One • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 146: Units For Sun And Wind

    Tables 6.1. Units for sun and wind The unit must receive values for rain, external temperature, wind speed and brightness from the bus in order to have the weather station initialised. The display of sun intensity is in lux or kilolux and is shortened in the display to lx or klx.
  • Page 147 Tables Sun direction Sun elevation Actuation position Slat position Slat 0°-15° position for 15°-30° Sun elevation 30°-45° 45°-90° TH sensor Yes/No Indoor temperature (°C) Night-time closure? Timed closure (period) Frost alarm? Outdoor temperature (°C) Wind alarm in (m/s), time overrun Rain alarm? Automatic Reset? Reset following manual...
  • Page 148 Tables Outdoor temperature block Yes/No Close from outdoor temperature (0.1 °C) Frost protection Yes/No Wind alarm Yes/No Rain alarm Yes/No Gap opening when raining Yes/No Gap opening (in %) Automatic Reset? Reset following manual? actuation? When the TH sensor is used: Indoor temperature block Yes/No Ondoor temperature...
  • Page 149 Tables Name Automatic Reset? Reset following manual? actuation? When the TH sensor is used: Name Indoor temperature lock Yes/No Indoor temperature (0.1 °C) Use air humidity Yes/No Air humidity (% rH) Use CO2 Yes/No CO2 content (10 ppm) Start exhaust ventilation (in 10%) and increase exhaust ventilation...
  • Page 150 Tables General automation settings: Twilight value (in lx) Extension delay (min) Retraction delay (min) Start night-time re-cooling when the external temperature is exceeded by (0.1 °C) for a period of (h) Start frost protection when the exterior temperature is exceeded (0.1 °C) for a set period following precipitation (in h) End frost protection when...
  • Page 151 Tables Name from Weekday Room Controller KNX Touch One • Status: 06.03.2017 • Errors excepted. Subject to technical changes.
  • Page 152 Elsner Elektronik GmbH Control and Automation Engineering Sohlengrund 16 75395 Ostelsheim Phone +49 (0) 70 33 / 30 945-0 info@elsner-elektronik.de Germany +49 (0) 70 33 / 30 945-20 www.elsner-elektronik.de Technical support: +49 (0) 70 33 / 30 945-250...