7 Operation Details

7.1.
Cooling Mode Operation
• • • • When selecting the Cooling Mode Operation, the unit will operate according to the setting by the Remote Controller and the
operation is as the following.
Time Delay Safety Control
• • • • 3 min. ---- The compressor is ceased for 3 minutes to balance the pressure in the refrigeration cycle.
• • • • (Protection of compressor).
Automatic Restarting Control
• • • • 7 min. ---- The unit will automatically operate in 7 minutes even if the room temperature is not reached.
(Prevention of raising the humidity)
Anti-freezing Control
• • • • If temperature of evaporator is lower than 2°C continuously
for 4 minutes, the compressor ill cease to prevent the
evaporator from freezing. Fan speed setting will not be
changed.
• • • • When
temperature
compressor will restart.
During Cooling Mode Operation, the Time Delay Safety Control
is available.
Compressor Protection Control
• • • • If the outdoor fan motor does not run 50 seconds after the compressor starts, the compressor will cease and restart in 3
minutes.(Time Delay Safety Control is effective.)
• • • • If this symptom occurs repeatedly 3 times, the compressor will stop.
• • • • If the operation mode changed or the unit turned off by remote controller, Compressor Protection Control will be reset.
Anti-reversing Control
• • • • If the compressor has been continuously running for 5 minutes, and the difference of temperature between intake air and
evaporator is continuously lower than 2.5°C or below for 2 minutes, the compressor is ceased for 3 minutes then restarts. (Time
Delay Protection Control is effective.)
of
evaporator
reaches
10°C,