Panasonic CS-SA9CKP Service Manual page 8

Hide thumbs Also See for CS-SA9CKP:
Table of Contents

Advertisement

CS-SA9CKP CU-SA9CKP5 / CS-SA12CKP CU-SA12CKP5
Air Circulation
Motor
Fan Speed
Heat Exchanger
Discription
Tube Material
Fin Type
Rows / Stage
FPI
Dimensions
Refrigerant Control Device
Refrigeration Oil
Refrigerant (R-22)
Thermostat
Protection Device
Capillary
Length
Circulation
Inner dia
Air Filter
Refrigerant Circulation Control Device
Compressor Capacitor
Fan Motor Capacitor
• • • • Specifications are subject to change without notice for further improvement
• • • • The amount of refrigerant (60g) for air purging not included
Unit
Type
Type
Input
W
Rate Output
W
Low
rpm
Medium
rpm
High
rpm
mm
(c.c)
mm
L/min
mm
µFV
µFV
CS-SA12CKP
Cross-flow Fan
Induction (4 pole)
13
980
1090
1200
Evaporator
copper
slot type
(Plate fin configuration, forced draft)
2 × 15
18
610 × 315 × 25.4
g
Electronic Control
P.P Honeycomb
1.5µF, 400V
8
CU-SA12CKP5
Propeller fan
Induction (6 pole)
58.6
20
750
Condenser
copper
Corrugation type
1 × 20
18
706.2 × 482.6 × 22
Capillary Tube
SUNISO 4GDID or ATMOS M60
(350)
940
Overload Protector
Cooling: 470, Heating: 1160
Cooling: 13.4, Heating: 4.5
Cooling: 1.5, Heating: 1.2
Capillary
30µF, 370V
1.8µF, 400V

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-sa12ckp5Cu-sa9ckp5Cs-sa12ckp

Table of Contents