If none of the 4 WAV Alarms are present, the WAV tile in APEX Fusion will show an OK status; if any enabled
WAV Alarm is active, it will be displayed on the Fusion tile.
On the WAV tile, a TEMP value equating to the current internal temperature of the WAV is displayed. The
normal range of TEMP will be 40-60%.
A new programming command has been introduced to allow WAV alarms to be reported via Apex email and
audible alarms, and via APEX Fusion email and SMS alerts. The syntax is:
If Error modulename Then [ON/OFF]
Here is an example used in a program for the email outlet:
Set OFF
If Temp < 77.0 Then ON
If Temp > 78.5 Then ON
If pH < 7.90 Then ON
If pH > 8.25 Then ON
If Leak1 CLOSED Then ON
If Error WAV_7 Then ON
WAV QuickStart Guide
Page 10