OVERHEATING: SAFETY DEVICES
The Aeroheaters incorporate thermal
protection which prevents the apparatus
from overheating by automatically
disconnecting the apparatus. This device
needs to be manually reset. If the device
activates, wait for 15 minutes to allow the
apparatus to cool, check that the grilles are
not dirty and, if necessary, disconnect the
apparatus from the mains supply and clean
them.
To operate the apparatus again, push the
RESET button located at the top of the
apparatus. (fig.7)
If the problem persists, contact S&P
Official Service Network.

MAINTENANCE

-
Disconnect the apparatus from the
mains electricity supply, using the
mains switch, before carrying out any
maintenance operations.
-
Each season, clean the accumulated
dust from the interior of the apparatus
using a compressed air jet to blow
through the inlet and outlet grilles.
This operation should be carried out
by a qualified technician.
-
Regularly clean the air inlet and outlet
grilles
-
Do not submerge the apparatus or pla-
ce it below a tap.
-
Do not disassemble or manipulate the
apparatus, as this will invalidate the
guarantee.
A sensitive internal differential switch
protects the appliance which sometimes
disconnects the apparatus from the supply.
This is normally due to the presence of
humidity in the heater elements. These
elements may accumulate humidity in their
interior when not used for long period of
time. This is not considered as a defect.
To correct the situation, connect the
apparatus to the mains without the
differential switch. The drying out period
could last hours or even days. A good
means to avoiding this situation is to
operate the apparatus periodically.
NOTE: To ensure safe and trouble free
operation is very important that the
appliance is cleaned at least once a year.
Standards: These apparatus comply with
the regulations governing radio-electrical
interference, and has the required
screening devices.

TECHNICAL ASSISTANCE

The extensive network of S&P Official
Service Agents guarantees technical
assistance in any place in Europe.
In the case that the product does not
operate correctly, please contact any of the
previously mentioned services to resolve
the problem.
Any manipulation of the apparatus made
by personnel other than S&P Official
Services will invalidate the guarantee.
S&P reserve the right to modify the product
without prior notice.