Battery Performance Test; Ac Generator (Charging Coil) Inspection - KYMCO Like 50 Service Manual

Table of Contents

Advertisement

15
. ELECTRICAL EQUIPMENT
PERFORMANCE TEST
Warm up the engine.
Remove the floor mat and front tool box
cover.
Use a fully charged battery to check the
charging system output.
Stop the engine and open the fuse box.
Disconnect the wire lead from the fuse
terminal. Connect an ammeter between
the wire lead and fuse terminal as shown.
Connect the battery positive (+) terminal to
the voltmeter positive (+) probe and battery
negative (-) terminal to the voltmeter
negative (-) probe.
Start the engine, gradually increase engine
speed to test the output:
Position
RPM
2500
1.3A min.
6000
2.0A min.
Charging Limit Voltage: 14.5±0.5V/8000rpm
If the limit voltage is not within the specified
range, check the regulator/ rectifier.
A.C. GENERATOR (CHARGING COIL)
INSPECTION
Inspect with the engine installed.
Remove the met-in box. ( 12)
Disconnect the A.C. generator connector.
Measure the resistances between the
charging coil terminals (white–green) and
lighting coil terminals (yellow–green).
Resistances:
Charging coil white–green 0.4~2Ω
Lighting coil
yellow–green 0.3~2Ω
Refer to 7-3 for A.C. generator removal.
5
Day
Night
1.0A min.
2.0A min.
A.C. Generator Connector
LIKE 50/125