Input for local devices

Output parameters based on
communication protocol
Level
Temperature (Product)
Vapor Temperature
Upper I/F (Water Level) *1
Middle I/F
Upper Density *2
Middle Densuty*3
Lower Density*4
Average Density *5
1-16 points Individual Density *6
Multi-Element Temperature
HART device input (Device 1)
HART device input (Device 2)
Alarm / Discrete Value
Protocol Documentation
8

Input

Signal
Power supply
Additional units

Output

V1(new)
V1 (old)
Yes
Yes
Yes
Yes
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
Yes
-
-
Remarks
1. Upper I/F output value can be either selected from the Proservo's own displacer measurement or Water
Bottom measured value via the Prothermo NMT 539.
2. A single point density measurement within the upper layer liquid in the tank. The measurement position
is configured to 150mm below the liquid surface at default.
3. A single point density measurement within the middle layer liquid in the tank. The measurement position
is configured to 150mm below the upper interface level at default.
4. A single point density measurement within the lower layer liquid in the tank. The measurement position
is configured to 150mm below the middle interface at default
5. The value of this "Average Density" is based on the calculation after performing the Density Profile oper-
ation at the Proservo.
6. All of the selected number of density measured value from 1 ~ 16 points can be transmitted.
Multi drop local HART® protocol max. 4 devices
DC 24V
NMT 53x average temperature sensor
NRF 560 field data processor
Other - compatible HART® devices
Spot temperature Pt 100 Ohm ISO standard three wire connection
MODBUS
HART
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-
Yes
-
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
KA0002N
-
WM550
ENRAF
Yes
Yes
Yes
Yes
Yes
-
Yes
Yes
-
-
Yes
-
-
-
Yes
-
-
-
Yes
--
Yes
-
Yes
-
Yes
Yes
KA001N
-
Endress+Hauser
Proservo
M/S
Yes
Yes
-
-
-
-
-
-
-
-
-
-
-
-
-

Advertisement