USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K
OPTIMA T09 1K/1.5K/2K/3K
UPS ONLINE DOUBLE CONVERSION
.
This manual Information cannot be copied or distributed
VER.170502-GA2 (ENG)
VER. 1705.02
ENGLISH
USER MANUAL
TOWER INSTALLATION
230V SCHUKO
120V NEMA
220V NEMA
INDEX
1

Advertisement

loading

Summary of Contents for Xmart OPTIMA T09 1K

  • Page 1 XMART is not responsible of mistakes or missing information in this manual. ▪ XMART is not responsible for wrong use a third part can do of this information. ▪ Trademarks and logos in this manual are property of their owners.
  • Page 2 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K TABLE OF CONTENTS 1. GENERAL SAFETY INSTRUCTIONS 2. SAFETY, QUALITY AND PERFORMANCE STANDARDS 3. PRODUCT DESCRIPTION 4. INSTALLATION 5. OPERATION MODES 6. OPERATION INTERFACE (KEYBOARD & LCD) 7. UPS CONFIGURATION 8. ERROR & ALARMS CODES 9.
  • Page 3 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K 1. GENERAL SAFETY INSTRUCTIONS WARNING: It is required to read and understand this manual. Follow all instructions given in this manual for starting up and operating this product. Only qualified technician must start-up, operate and maintain this product. Keep manuals as a guide for future consults.
  • Page 4 It also could affect its performance and the compliance of regulations. XMART is not responsible of modifications made after manufacturing. WARNING: This is a category C2 UPS product. In a residential environment, this product may cause radio interference, in which case the user may be required to take additional measures (only for 220/230/240VAC systems).
  • Page 5 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K 4. INSTALLATION AC CONNECTIONS Install this UPS indoors with a conditioned temperature free of dust. The site conditions must comply with room specifications required in the specifications table of this manual. Plug UPS input power-cord to the wall socket with rated voltage according to your UPS model.
  • Page 6 T09 1.5K: 36VDC T09 2K: 72VDC T09 3K: 72VDC Place UPS module close to original XMART XBAT modules. Check all DC switches on XBAT are in OFF position. Connect UPS to first XBAT module by using original DC cable In case system has more than 1 XBAT, connect XBAT#1 to XBAT#2. Then XBAT# 2 to XBAT#3 and so on.
  • Page 7 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K 5. OPERATION MODES This is a True Online Double Conversion UPS and it is designed to offer clean, bump-less and highest quality power to your computer related equipment protecting also your valuable data. Power delivered by UPS is 100% sine wave as main line.
  • Page 8 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K A – In online mode, Input voltage indicates a valid AC input close to (232VAC). B – Output voltage is displayed in upper left ONLINE corner (B) C – Flowchart indicates AC input is used to recharge batteries but also feeds rectifier input.
  • Page 9 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K 6. OPERATOR INTERFACE: KEYBOARD & LCD FRONT PANEL: <ON / MUTE> UPS TURN-ON: Keep it pushed during 2 seconds. Is button is release before required time UPS will not turn on. ALARM MUTE...
  • Page 10 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K LCD DESCRIPTION LCD can be divided in 6 functional areas: OUTPUT INFORMATION: It displays: AC Input voltage, DC Battery voltage, Input frequency (in Hz) INPUT INFORMATION: It displays: AC output voltage, Output frequency (in Hz) ALARMS &...
  • Page 11 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K FLOWCHART – UPS STATES & MODES This section displays graphically operation mode and state of the UPS: (1) : Valid AC Input detected (2) : Battery symbol (3) : Converters (Rectifier & Inverter)
  • Page 12 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K 7. UPS CONFIGURATION Configuration menu allows setting of functions and parameters of the UPS. Menu is activated by pressing < SELECT > during 5 seconds with UPS in STAND-BY or BYPASS mode (powered but without activation of ON button).
  • Page 13 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K CF: ENABLE / DISABLE FREQUENCY CONVERTER FUNCTION: CF can be enable/disable by setting PAR. 03: CF = Enable NCF = Disable If CF is enable PAR 02 must be set to preferred frequency value: 50Hz or 60Hz...
  • Page 14 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K PROG-OUTPUT: ENABLE / DISABLE PROGRAMMABLE OUTPUTS: Enables/disables programable output (check function 11) ENA : ENABLE DIS : DISABLE Factory set: DIS PROG-OUTPUT: MAXIMUM RUNTIME FOR PROGRAMMABLE OUTLETS: 0-999: Time in minutes for programable outlets in Battery mode (if function 10 is enable).
  • Page 15 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K LCD CODES AND TEXTS: TEXT DESCRIPTION Battery (Batería) Battery AH (AH de las baterías) Battery Replacement (ReemplazarBaterías) Charger Boost Voltage (Voltaje del cargador de baterías) Charger Float Voltage (Voltaje flotante de recarga de baterías) Frequency Converter Function (Función de Convertidor de Frecuencia)
  • Page 16 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K 8. ALARM & ERROR CODES IMPORTANT: All alarms and errors are informed on the LCD by dedicated codes and symbols. ALARMS: Are usually represented by blinking codes or symbols. Audible alarm beeps are also intermittent for ▪...
  • Page 17 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K ERROR CODES Error states are produced when UPS detects a critical problem that avoids its normal operation in ONLINE mode. This condition is described by steady symbol and code on LCD. A continuous beep is also generated by the UPS.
  • Page 18 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K 9. TROUBLESHOOTING PROBLEM PROBABLE CAUSE & SOLUCION Low Batteries Charge: Recharge Batteries during 4-6 h. Short runtime in Battery mode Old Batteries: Batteries must be replaced by new ones ALARMS PROBABLE CAUSE & SOLUCION High power consumption connected to UPS: Disconnect no critical equipment from UPS.
  • Page 19 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K 10. SOFTWARE Our monitoring software allows user to manage UPS and monitoring of all of its features. Main software features are: Configuring UPS parameters, Automatic shutdown for protected PCs (OS and files) when long blackouts force UPS to power-off, Scheduled battery tests, shutdown and start-up and Easy interface for monitoring UPS and Main service.
  • Page 20 - In no event will XMART be liable for any damages caused by the product or the failure of the product to perform, including any lost profits or savings or special, incidental, or consequential damages.
  • Page 21 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K 14. FRONT & REAR PANEL 1.- Standard UPS Outlets 6.- Emergency Power Off connector 2.- Programmable Outlets 7.- USB & RS232 3.- AC Input 8.- Intelligent port 4.- Input AC Breaker 9.- DC connector for external batteries 5.- Surge Protected RJ45 sockets...
  • Page 22 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K 15. SPECIFICATIONS (1/2) OPTIMA T09 1.5K Capacity / Capacidad (VA) 1000VA 1500VA 2000VA 3000VA Capacity / Capacidad (W) 900W 1350W 1800W 2700W INPUT / ENTRADA Range / Rango - 120V Model 120V: 80Vac-150Vac @ 100% load...
  • Page 23 INDEX USER MANUAL - OPTIMA T09 1K/1.5K/2K/3K 15. SPECIFICATIONS (2/2) OPTIMA T09 1.5K PRODUCT FEATURES / CARACTERISTICAS DEL PRODUCTO 397x145x220 397x145x220 421x190x318 421x190x318 DxWxH / Prof.*Ancho*Altura (mm) Net Weight / Peso Neto (kgs) UPS MODEL: 230Vac (EUROPE) SCHUKO x 2...
  • Page 24 NOTAS...
  • Page 28 EUROPE Latin America 10540 NW 26th St, Ave. Can Bordoll 60, Nave 4. Zona Ind. San Vicente II, C/ F, A11 Doral, FL 33172. USA Sabadell 08202. Spain Maracay. Venezuela sales@xmart-ups.com sales@xmart-ups.com sales@xmart-ups.com...

This manual is also suitable for:

Optima t09 1.5kOptima t09 2kOptima t09 3k