Outdoor
Combination
68/57
air temp.
(%)
TC
(°F DB)
MBh
-9.9
152.8
-5
152.8
0
152.8
5
152.8
10
152.8
14
152.8
20
152.8
25
152.8
30
152.8
35
152.8
40
152.8
45
152.8
50
152.8
55
152.8
130%
60
152.8
65
152.8
70
152.8
75
152.8
80
152.8
85
152.8
90
152.8
95
154.4
100
154.4
105
154.4
110
154.4
115
153.6
118
133.6
122
106.7
-9.9
139.0
-5
139.0
0
139.0
5
139.0
10
139.0
14
139.0
20
139.0
25
139.0
30
139.0
35
139.0
40
139.0
45
139.0
50
139.0
55
139.0
120%
60
139.0
65
139.0
70
139.0
75
139.0
80
139.0
85
139.0
90
139.0
95
140.5
100
140.5
105
140.5
110
140.5
115
136.6
118
122.0
122
97.5
TC = Total Capacity (MBh).
PI = Power Input (kW) (includes compressor and outdoor fan).
Cooling range with the Low Ambient Baffle Kit (sold separately) is -9.9°F to +122°F and is achieved
only when all indoor units are operating in cooling mode. Does not impact heat recovery system
synchronous operating range.
The System Combination Ratio must be between 50–130%.
73/61
79/64
PI
TC
PI
TC
kW
MBh
kW
MBh
3.92
181.5
4.75
210.9
4.13
181.5
5.01
210.9
4.30
181.5
5.22
210.9
4.46
181.5
5.41
210.9
4.58
181.5
5.56
210.9
4.75
181.5
5.76
210.9
4.83
181.5
5.86
210.9
4.90
181.5
5.93
210.9
4.97
181.5
6.01
210.9
5.02
181.5
6.09
210.9
5.09
181.5
6.15
210.9
5.14
181.5
6.22
210.9
5.19
181.5
6.28
210.9
5.28
181.5
6.39
210.9
5.45
181.5
6.62
207.8
5.56
181.5
6.77
204.7
5.35
181.5
6.50
200.9
5.49
181.5
6.93
197.8
6.24
181.5
7.89
192.3
6.64
181.5
8.43
189.2
7.52
178.4
9.58
183.8
7.97
177.1
10.20
182.6
8.63
174.0
11.03
179.5
9.73
169.3
12.48
174.8
10.93
162.3
14.06
169.1
12.64
156.4
16.17
156.4
10.71
136.0
13.70
136.2
8.13
109.1
10.42
108.5
3.69
165.9
4.47
192.8
3.89
165.9
4.72
192.8
4.05
165.9
4.91
192.8
4.20
165.9
5.09
192.8
4.32
165.9
5.24
192.8
4.48
165.9
5.43
192.8
4.55
165.9
5.51
192.8
4.60
165.9
5.57
192.8
4.66
165.9
5.64
192.8
4.72
165.9
5.71
192.8
4.78
165.9
5.78
192.8
4.84
165.9
5.84
192.8
4.89
165.9
5.91
192.8
4.97
165.9
6.02
192.8
5.13
165.9
6.24
192.8
5.24
165.9
6.37
192.8
5.14
165.9
6.24
192.8
5.27
165.9
6.65
192.8
5.99
165.9
7.58
187.4
6.37
165.9
8.09
184.3
7.22
165.9
9.20
179.0
7.66
167.7
9.79
177.7
8.29
167.7
10.59
174.6
9.34
165.0
11.99
170.0
10.49
160.8
13.50
166.0
12.14
154.9
15.53
154.9
10.71
134.7
13.15
134.9
8.13
108.0
10.00
107.5
©
COOLING CAPACITY DATA

ARUM168BTE5 / ARUM168DTE5

168,000 Btu/h 208-230V / 460V Outdoor Units

Indoor Air Temp. °F DB/°F WB
80/67
85/70
PI
TC
PI
TC
kW
MBh
kW
MBh
5.64
218.7
6.09
221.8
5.95
218.7
6.42
221.8
6.19
218.7
6.68
221.8
6.42
218.7
6.93
221.8
6.60
218.7
7.12
221.8
6.84
218.7
7.38
221.8
6.94
218.7
7.50
221.8
7.02
218.7
7.59
221.8
7.11
218.7
7.68
221.8
7.19
218.7
7.77
221.8
7.28
218.7
7.87
221.8
7.36
218.7
7.95
221.8
7.43
218.7
8.03
221.8
7.57
215.6
8.20
218.7
7.89
210.8
8.52
213.3
8.03
207.8
8.69
210.2
8.00
203.2
8.80
206.3
8.56
200.1
9.45
203.2
9.79
194.7
10.81
197.8
10.46
192.3
11.53
194.7
11.88
186.1
13.14
189.2
12.68
188.1
185.7
14.02
13.75
182.6
14.76
185.0
15.51
177.5
15.87
180.2
16.92
169.6
17.00
172.1
17.83
156.4
17.83
156.4
15.00
136.2
15.13
136.2
11.42
108.8
11.44
109.1
5.30
206.6
5.71
215.8
5.59
206.6
6.03
215.8
5.81
206.6
6.27
215.8
6.03
206.6
6.50
215.8
6.20
206.6
6.69
215.8
6.42
206.6
6.93
215.8
6.52
206.6
7.03
215.8
6.59
206.6
7.12
215.8
6.67
206.6
7.21
215.8
6.75
206.6
7.31
215.8
6.84
206.6
7.39
215.8
6.92
206.6
7.48
215.8
6.99
206.6
7.56
215.8
7.13
206.6
7.72
213.5
7.43
205.1
8.02
207.4
7.56
202.0
8.18
205.1
7.68
198.2
8.45
200.5
8.22
195.1
9.07
198.2
9.40
189.7
10.38
192.0
10.05
186.6
11.07
189.7
11.41
181.3
12.61
183.6
12.18
183.2
180.1
13.46
177.7
14.17
180.1
13.20
14.90
172.7
15.23
175.0
16.24
166.5
16.32
169.0
17.12
154.9
17.12
154.9
14.40
134.9
14.53
134.9
10.96
107.8
10.99
108.0
Nominal capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping.
0 ft. level difference between outdoor and indoor units.
Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and
67ºF wet bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
88/73
91/76
PI
TC
PI
TC
kW
MBh
kW
MBh
6.57
229.5
7.53
235.0
6.93
229.5
7.94
235.0
7.21
229.5
8.26
235.0
7.47
229.5
8.56
235.0
7.69
229.5
8.81
235.0
7.96
229.5
9.13
235.0
8.07
229.5
9.26
235.0
8.17
229.5
9.36
235.0
8.26
229.5
9.47
235.0
8.36
229.5
9.58
235.0
8.46
229.5
9.69
235.0
8.54
229.5
9.80
235.0
8.63
229.5
9.89
235.0
8.80
226.4
10.06
231.8
9.15
220.9
10.38
226.4
9.32
217.7
10.72
223.2
9.66
213.8
10.73
219.3
10.36
210.7
11.24
216.2
11.88
205.2
12.20
210.7
12.60
202.1
12.71
207.6
13.59
196.6
13.70
202.1
14.08
195.5
14.21
201.1
14.84
193.1
14.98
198.7
15.95
186.4
16.10
189.1
17.06
175.7
17.22
176.4
17.83
158.7
17.87
159.4
15.13
138.2
15.16
137.6
11.46
110.9
11.49
110.8
6.16
225.6
7.06
230.3
6.50
225.6
7.45
230.3
6.76
225.6
7.75
230.3
7.01
225.6
8.03
230.3
7.21
225.6
8.27
230.3
7.47
225.6
8.56
230.3
7.58
225.6
8.69
230.3
7.67
225.6
8.79
230.3
7.75
225.6
8.89
230.3
7.85
225.6
8.99
230.3
7.95
225.6
9.11
230.3
8.04
225.6
9.21
230.3
8.13
225.6
9.32
230.3
8.29
222.5
9.48
228.0
8.61
217.0
9.77
221.7
8.78
213.9
10.10
219.4
9.27
210.0
10.30
214.7
9.94
206.8
10.79
212.3
11.41
201.3
11.72
206.0
12.10
198.2
12.20
203.7
13.05
192.7
13.15
197.4
13.51
191.6
13.64
197.1
14.25
189.2
14.38
194.0
15.32
183.7
15.45
186.8
16.37
174.2
16.53
174.9
17.12
158.7
17.15
159.4
14.53
138.2
14.55
137.6
11.00
111.0
11.03
110.8
PERFORMANCE DATA | 25
PI
kW
7.78
8.21
8.54
8.85
9.10
9.43
9.57
9.68
9.80
9.91
10.03
10.13
10.24
10.31
10.42
10.81
10.84
11.32
12.31
12.82
13.84
14.34
15.11
16.25
17.39
17.90
15.19
11.54
7.30
7.70
8.01
8.30
8.54
8.85
8.98
9.09
9.20
9.31
9.43
9.54
9.64
9.71
9.95
10.18
10.40
10.87
11.82
12.31
13.28
13.77
14.51
15.59
16.69
17.18
14.58