TO CHARGE THE BATTERIES
!
CAUTION
When servicing machine, avoid contact with
battery acid.
!
WARNING
Batteries emit hydrogen gas. Explosion or fire
can result. Keep sparks and open flame away.
Keep covers open when charging.
!
WARNING
Wear eye protection and protective clothing
when working with batteries.
!
WARNING
Charge batteries in a well ventilated area. Leave
the solution tank open.
Use a 36 volt, 20 amp maximum output, DC charger
which will automatically shut off when the batteries
are fully charged.
1. Stop the machine in a clean, well ventilated area
next to the charger.
2. Turn "OFF" machine and set parking brake.
FOR SAFETY: Before leaving or servicing
machine; stop on level surface, set parking
brake, turn off machine and remove key.
3. Drain solution tank and raise the solution tank
and lock the support arm. Make sure the
support arm is fully engaged.
!
WARNING
Batteries emit hydrogen gas. Explosion or fire
can result. Keep sparks and open flame away.
Keep covers open when charging.
4. Check the electrolyte level in each battery cell.
Before charging, add just enough distilled water
to cover the plates. After charging is complete,
add just enough distilled water to bring up the
level to the indicator ring. If the water level is
too high before charging, normal expansion rate
of the electrolyte may cause an overflow.
Resulting in a loss of battery acid balance and
damage the machine.
5. Replace the battery caps, and leave them in
place while charging.
6. Unplug the battery connector from the machine.
FOR SAFETY: When charging, connect the
charger to the batteries before connecting the
charger to the AC wall outlet. Never connect the
charger to the AC wall outlet first. Hazardous
sparks may result.
7. Plug the charger connector into the battery
8. When the batteries are fully charged, disconnect
9. Connect the batteries to the machine connector.
10. Check the electrolyte level. It should be up to
11. Lower the solution tank.

CHANGING BATTERIES

Stop the machine in a clean area next to the
charger. Turn off machine.
FOR SAFETY: Before leaving or servicing the
machine; stop on level surface, set parking
brake, turn off machine and remove key.
1. Raise the solution tank.
2. Engage solution tank support arm.
3. Disconnect battery pack from machine.
4. Use the proper size open end wrench to
5. Disconnect main positive lead and secure cable
6. Loosen both terminals on each jumper cable
7. Prepare a suitable site to place the batteries.
8. Attach suitable battery lifting device and lift
Batteries are a potential environmental hazard.
Consult your battery supplier for safe disposal
methods.
STRIDE2 36V (SX) 98745 01/07/00
connector. Connect the charger AC plug to a
wall outlet. The charger gauge should indicate
that the batteries are charging.
the charger from the AC wall outlet, then
disconnect the charger from the batteries.
the indicator ring. If necessary, add distilled
water.
disconnect main ground wire first and secure
cable terminal away from batteries.
terminals away from batteries.
and remove one at a time.
batteries from the machine.
!
WARNING
_
BLK
RED
RED
_
BLK
MAINTENANCE
_
_
BLK
BLK
RED
RED
RED
RED
_
_
BLK
BLK
+
_
4-2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents