JLG 600SC Operator's And Safety Manual page 45

Telescopic crawler boom lift
Table of Contents

Advertisement

3. Plug tool it into quick-disconnect fittings mounted on
platform rail. The male quick connect is the pressure
feed line.
4. Set flow control knob to desired setting.
NOTE: Each notch in the flow control knob corresponds to
approximately 1 GPM (ex. setting 2 = 2 GPM). At
setting seven (7) the pump has reached its maximum
flow rate therefore any setting past 7 will produce no
additional flow.
3120897
SECTION 3 - USER RESPONSIBILITIES AND MACHINE CONTROL
TURN HYDRAULIC TOOL SWITCH TO THE "OFF" POSITION IN
ORDER TO SWITCH TOOLS.
NOTE: The tool circuit will not work with the foot switch
NOTE: The tool is designed to operate at 2600 psi. If neces-
NOTE: With the foot switch released to operate the tool cir-
– JLG Lift –
5. Turn hydraulic powertool switch to the "ON" posi-
tion. Oil will now flow to the tool. It is possible to
adjust the flow control knob during operation to
achieve desired tool performance.
6. When finished, turn the hydraulic tool switch to the
"OFF" position.
7. Disconnect tool from the quick-disconnects.
depressed. If the foot switch is depressed during tool
circuit operation the tool circuit will stop functioning
until the foot switch is released.
sary this can be adjusted for a higher or lower pres-
sure.
cuit all drive and boom functions are cut out.