Emergency Ground Egress; Revision A1 - Cirrus SR20 Pilot Operating Handbook

Table of Contents

Advertisement

Section 3
Emergency Procedures
Amplification
Use caution after shutdown if STARTER circuit breaker
required pull (failed relay or solenoid). If breaker is
unknowingly or unintentionally reset, starter will instantly
engage if Battery 1 power is supplied; creating a hazard for
ground personnel.
Starter has been engaged for more than 15 seconds (starter limit is 10
seconds); if not manually engaged, such as during difficult start, this
annunciation may indicate a failure of the starter solenoid or a stuck
keyswitch.

Emergency Ground Egress

1. Engine........................................................................SHUTDOWN
2. Seat belts ....................................................................... RELEASE
3. Airplane ...................................................................................EXIT
Amplification
While exiting the airplane, make sure evacuation path is clear
of other aircraft, spinning propellers, and other hazards.
If the engine is left running, set the Parking Brake prior to evacuating
the airplane.
If the doors cannot be opened, break out the windows with egress
hammer, located in the console between the front seats, and crawl
through the opening.
3-32
• WARNING •
• WARNING •
Cirrus Design
SR20
P/N 21399-004

Revision A1