Smoke And Fume Elimination; Reissue A - Cirrus SR20 Pilot Operating Handbook

Table of Contents

Advertisement

Cirrus Design
SR20

Smoke and Fume Elimination

1. Air Conditioner (if installed)...................................................... OFF
2. Temperature Selector ........................................................... COLD
3. Vent Selector ........................ FEET/PANEL/DEFROST POSITION
4. Airflow Selector .............................. SET AIRFLOW TO MAXIMUM
If source of smoke and fume is firewall forward:
a. Airflow Selector ................................................................. OFF
5. Panel Eyeball Outlets............................................................ OPEN
6. Prepare to land as soon as possible.
Amplification
If smoke and/or fumes are detected in the cabin, check the engine
parameters for any sign of malfunction. If a fuel leak has occurred,
actuation of electrical components may cause a fire. If there is a strong
smell of fuel in the cockpit, divert to the nearest suitable landing field.
Perform
Forced Landings
the engine once a safe landing is assured.