11. SPF SECTION <AL-1622 ONLY>
A. Remove the SPF
1) Remove the SPF connector.
Connect the interface harness extended from the SPF, and fix with the
hand screws.
2) Remove the PWB shield plate.
Remove the six screws.
3) Remove the SPF harness and the ring core (included together
with the unit).
Pass the SPF harness through the ring core (2), and connect it to the
main PWB connector (CN11) inside the copier. (3)
Be careful about the direction
of the connector.
(3)
(2)
AL-1611/AL-1622 DISASSEMBLY AND ASSEMBLY
11 – 12
Pass the SPF harness through the plate hole from the above and fix it
to the plate with the supplied two hex cap screws. (1)
4)
Remove the SPF to copier.
Tilt the SPF backward and insert into the hinge guide.
B. External fitting section
Note: Remove the pawl in the arrow direction.
2
(1)
2
1