Other Measurement Specifications
Measurement Function
Input Bandwidth: (-0.5 dB):
Crest Factor (CF): (Using
Smooth % 20)
Power Factor (PF):
Displacement Power
Factor (DPF):
Phase Measurement
Range:
K-Factor (KF) Model 41B:
Total Harmonic Distortion
(THD)
%THD-F:
%THD-R:
Range/Resolution
DC 6 Hz to 2.1 kHz
1.00 to 5.00
0.00 to 1.00
0.00 to 0.29
0.30 to 0.69
0.70 to 0.89
0.90 to 1.00
-179 to 180 degrees
1.0 to 30.0
0.0 to 799.9
0.0 to 99.9
Specifications
Accuracy
± 4%
± 0.02
unspecified
± 0.04
± 0.03
± 0.02
± 10%
± (0.03 x Reading + 2.0%)
± (0.03 x Reading + 2.0%)