Cal Spas PATIO Owner's Manual page 30

2017 portable spas
Hide thumbs Also See for PATIO:
Table of Contents

Advertisement

28
Setting Dual Temperature Ranges
This system incorporates two temperature range settings with independent
set temperatures. The specific range can be selected on the Settings screen
and is visible on the Main Screen in the upper right corner of the display.
These ranges can be used for various reasons, with a common use being
a "ready to use" setting vs. a "vacation" setting. Each range maintains its
own set temperature as programmed by the user. This way, when a range is
chosen, the spa will heat to the set temperature associated with that range.
High Range can be set between 26.5°C and 40°C (80°F and 104°F). Low
Range can be set between 10°C and 37°C (50°F and 99°F). More specific Temp Ranges may be determined
by the Manufacturer. Freeze Protection is active in either range.
Selecting Heat Modes – Ready vs . Rest
In order for the spa to heat, a pump needs to circulate water through the
heater. The pump that performs this function is known as the "heater pump."
The heater pump can be either a 2-speed pump (Pump 1) or a circulation
pump. If the heater pump is a 2-Speed Pump 1, Ready Mode will circulate
water every 1/2 hour, using Pump 1 Low, in order to maintain a constant
water temperature, heat as needed, and refresh the temperature display.
This is known as "polling."
Rest Mode will only allow heating during programmed filter cycles. Since
polling does not occur, the temperature display may not show a current temperature until the heater pump
has been running for a minute or two. While Pump 1 High can be turned on and off, Pump 1 Low will run until
set temperature is reached, or 1 hour has passed.
Circulation Mode
If
the
spa
circulation, the heater pump generally runs
continuously. Since the heater pump is
always running, the spa will maintain set
temperature and heat as needed in Ready
Mode, without polling. In Rest Mode, the
spa will only heat to set temperature during
programmed filter times, even though the
water is being filtered constantly when in
Circulation Mode.
Ready-in-Rest Mode
READY/REST appears in the display if the spa is in Rest Mode and the Jets
1 Button is pressed. It is assumed that the spa is being used and will heat
to set temperature. While Pump 1 High can be turned on and off, Pump 1
Low will run until set temperature is reached, or 1 hour has passed. After 1
hour, the System will revert to Rest Mode. This mode can also be reset by
entering the Settings Menu and changing the Heat Mode.
www.calspas.com
is
configured
for
24HR
Filter Cycles
Filter Cycle 1
Starts at 12:00 AM
Back
Runs 0 HR 0 Min
Ends at 12:00 AM
Filter Cycle 2 NO
Starts at 12:00 AM
Runs 0 HR 0 Min
Ends at 12:00 AM
Settings
Temp Range
High
Heat Mode
Ready
Back
Time of Day
Filter Cycles
Light Cycle
Invert Panel
Normal
Lock
Settings
Temp Range
High
Back
Heat Mode
Ready
Time of Day
Filter Cycles
Light Cycle
Invert Panel
Normal
Lock
Filter Cycles
Filter Cycle 1
Starts at
6:15
AM
Back
Save
Runs
3
HR 0 Min
Ends at 9:15 AM
Cancel
Filter Cycle 2 NO
Starts at 12:00 AM
Runs 0 HR 0 Min
Ends at 12:00 AM
39°C
Haute Gamme
Set: 40°F
8:32 PM
Scènes
Ozone
Paramètres
Filtre 1
Prêt/Repos
Chauffage
2017 Portable Spa
LTR20171001, Rev. B
Spa

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

EscapePatio plusEscape plusSpecial edition