Remove the head from the adapter and fix the new head
11
to the adapter.
Make sure to fix the head by pressing it to the
bottom left corner of the adapter.
Use the 2kgf·cm torque driver (ST-056) to
tighten up the screws.
Install the head to the Head Carriage and fix the 3 screws
12
temporarily. Then, fix the spring and tighten up the 3
screws in order as shown in the figure.
Use the 2kgf·cm torque driver (ST-056) to
tighten up the screws.
Connect the 2 flexible cables to the Head Board.
13
Do not connect the cables to the wrong
connecter.
Fix the Head Board Cover.
14
When fixing the Head Board Cover, hook the
tab to the Carriage Base.
CARRIAGE
BASE
TAB
ADAPTER
2
1
FLEXIBLE CABLE
HEAD BOARD COVER
3-7
HEAD
5CY2F2F
3
SPRING
SCREW