In an installation room with ventilation air supplied through the external wall

A
B
A Flue gas
B Ventilation air
1.8 Flue installation options for open flue operation
(Separate ventilation air aperture with 150 cm
Shown with the Vitoladens 300-W.
In an installation room (non-living space) with one or more full storeys above
A
B
A
B
C
A Flue gas
B Secondary ventilation
C Ventilation air
A
B
C
A Flue gas
B Secondary ventilation
C Ventilation air
VITOLADENS, VITORONDENS
Separate ventilation air and flue gas routing
(type C
The boiler draws combustion air from outside via a separate supply
pipe routed through the external wall, and expels flue gas to the atmos-
phere via a shaft leading through the roof.
The connection piece to the chimney is designed as a coaxial pipe.
This balanced flue system is used if the existing chimney is unsuitable
for routing combustion air due to its dimensions or characteristics
(deposits).
For a detailed description, see page 31.
2
2
or 2 × 75 cm
cross-section required)
Routing through a shaft
(type B
The boiler draws combustion air from the installation room and expels
flue gas through the flue via the roof (balanced flow).
For a detailed description, see page 34.
Connection to a moisture-resistant chimney (MR chimney)
(type B
The boiler draws combustion air from the installation room and routes
flue gas through the moisture-resistant chimney via the roof.
For a detailed description, see page 37.
, to TRÖl 2009)
83x
, to TRÖl 2009)
23
, to TRÖl 2009)
23
1