Flue, System Size 80 And 100 (Components) - Viessmann Vitoladens 300-C Technical Manual

Flue systems for oil condensing boilers
Table of Contents

Advertisement

Design and sizing information for the Vitoladens 300-C, -T, and Vitorondens 200-T, 222-F
Minimum internal shaft dimensions to DIN V 18160
System size A
80
80 (flexible)
100
100 (flexible)
Max. number of bends:
■ 87º: 3 pce
or
■ 45º: 3 pce
or
Flue, system size 80 and 100 (components) (type B
E
5
6
E
A
C
4
D
3
1
E
Illustration with the Vitoladens 300-C
A Ventilation air aperture, min. 150 cm
B Flue gas
VITOLADENS, VITORONDENS
External diameter;
female connection a
Ø mm
94
100
128
125
B
2
3
4
C
2
3
2
3
2
2
2
or 2 × 75 cm
2
Minimum internal shaft dimension
b
square or rectangular
(short side)
mm
135
140
170
165
■ 30º: 4 pce
or
■ 15º: 4 pce
The annular gap must be at least 3 cm wide at the shaft inlet.
to TRÖI 2009)
23
C Inspection port
D Connection piece = ¼ of the vertical length or max. 3 m
E Secondary ventilation
Rated heating output (kW)
1 Boiler flue connection (part of the stand-
ard boiler delivery)
2 Standard shaft pack (PPs, rigid)
Comprising:
– Support bend
– Support rail
– Shaft cover (PPs)
– Spacers (5 pce, max. clearance 5 m)
or
Standard shaft pack (metal/PPs, rigid)
For twin flue chimneys; one flue for solid
fuel boilers
Comprising:
– Support bend
– Support rail
– Shaft cover (metal)
– Terminal pipe (stainless steel)
– Spacers (5 pce, max. clearance 5 m)
Spacers (3 pce, max. clearance 5 m)
3 Pipe
1.95 m long (2 pce = 3.9 m)
1.95 m long (1 pce)
1 m long (1 pce)
0.5 m long (1 pce)
4 Inspection piece, straight (1 pce)
5 Bend
87º (1 pce)
45º (2 pce)
6 Ventilation bezel (1 pce)
Bend (for use in corbelled chimneys)
30º (2 pce)
15º (2 pce)
Inspection tee 87º (1 pce)
Inspection bend 87º (1 pce)
(cont.)
c
round
Ø mm
155
160
190
185
up to
from
35.4
42.8
System size
Ø mm
80
100
80
100
80
100
80
100
80
100
80
100
80
100
80
100
80
100
80
100
VIESMANN
21