Camera Control And Performing A Scan; Software: Sklinescan; Function Overview: Sklinescan Toolbar - Schäfter+Kirchhoff SK22368U3TOC-LA Instruction Manual

Color line scan camera 3x 7456 pixels, 4.7 µm x 4.7 µm, 150 / 75 mhz pixel frequency
Table of Contents

Advertisement

3

Camera Control and Performing a Scan

3.1

Software: SkLineScan

This section is a brief introduction to the SkLineScan adjustment and configuration software. A more detailed
description is provided in the separate SkLineScan manual. The pdf is included in the SkLineScan installation
package or is available for download from the Schäfter + Kirchhoff website under http://www.sukhamburg.com/
support.html.
For an in-depth guide on how to perform imaging and to use the obtained data using the Schäfter + Kirchhoff
software package, see the SkLineScan Software Manual.
The most common functions of the line scan camera can be controlled by menu items and dialog boxes.
Commands controlling comprehensive camera functionality can be entered in the "Camera Gain / Offset
Control" dialog.
Click on the desktop icon to start the SkLineScan
program.
The SkLineScan program recog nizes the connected line
scan cameras automatically. The identified cameras are
shown in the start-up dialog
corresponds with the individual MAC addresses of the
cameras.
If the SK22368U3TOC-LA camera is identified correctly,
confirm with "OK". The "Signal window" graphicaly
showing the intensity signals of the sensor pixels (oscil-
loscope display) will open. It is responsive in real-time
and the zoom function can be used to highlight an area
of interest. The oscilloscope display is ideally suited for
parameterizing the camera, for evaluating object
illumination, for focussing the image or for aligning the
line scan camera correctly.

Function Overview: SkLineScan Toolbar

New line scan. All open "Signal window" windows will be closed. [F2]
"Camera Control" dialog for parameter settings: integration time, line frequency, synchronization
mode, thresholding
Zooming in and out
New line scan. "Area Scan" windows will be closed, "Signal window" windows will remain open. [F2]
Threshold mode in new binary signal window.
"Shading Correction" dialog to adjust the white balance [Alt + s]
"Gain/Offset Control" dialog, also for commands input [Shif+F4]
New area scan
9
, and the index order
A
SK22368U3TOC-LA Instruction Manual (12.2016)
Camera Control and Performing a Scan
A
SkLineScan: Start-up dialog
SkLineScan: Toolbar
© 2016
Schäfter + Kirchhoff GmbH • Hamburg