Hitachi CMP5000WXJ Service Manual page 35

Sm 0067
Hide thumbs Also See for CMP5000WXJ:
Table of Contents

Advertisement

1
3.1.7 SUB ADDRESS A and B ASSYS
+60V
ADRGND
CN8801
H : V MID CLAMP OFF
L : V MID CLAMP ON
V MID SW
ADRK EMG1
+12V
DGND
ADR-B
ADR-U
ADR-D
ADRK. PD
CN8802
SW
ADR-D
ADR-U
ADR-B
+12V
DGND
VADR
ADRGND
ADROUT
CN8803
H : EMG1 OFF
L : EMG1 ON
1
2
Current - Voltage
Convert Block
R8801 - R8805
P.D. Output Block
Q8803, Q8831
BUFF Block
IC8801
(DC+AC)
(-AC)
Additional
(DC)
Block
IC8802
2
3
Over Current DET. Block
ADR Output
Resistance Load Block
ADR EMG 1 Block
Inversion
+5V REG
Block
IC8801
Conparator
CLK
Flip / Flop
(EMG : ON)
IC8802
Conparator
CLR
(EMG : OFF)
IC8804
3
4
A
Q8801
Q8805, Q8806
12V
B
D8804
5V
IC8803
C
D
35
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cmp5000wxuCmp5000wxe

Table of Contents