Alarm name
Alarm type
Auto release Safety Alarm
Drive
Safety Alarm
stopped
No Control
Safety Alarm
Head
No Drive
Safety Alarm
Detected
Pilot controller alarms
Description
Action
Appears
• Pilot drops
when the
to standby
user has
and alarm
taken back
times out
control of
after 10
the steering
seconds.
whilst in an
engaged
mode (Auto,
Track, etc)
using the
fly-by-wire
steering
wheel.
Indicates a
• Check out-
rudder stall
put from
condition has
SPX, drive
persisted
unit and
or that
connec-
the power
tions.
has been
• Pilot drops
removed
to standby
from the
and alarm
drive unit.
times out
Initiated in
after 10
Auto, Track &
seconds.
Wind modes.
The course
• Check
computer has
connec-
lost commu-
tions for
nications with
short or
the Pilot con-
open cir-
troller, this
cuit.
alarm is gen-
• Check
erated by the
system
course com-
for device
puter.
fault.
• Pilot drops
to standby
and alarm
times out
after 10
seconds.
Communica-
• Check
tion between
LED diag-
the EV unit
nostics in-
and ACU has
dicators.
been lost or
• Check
cannot be es-
output
tablished.
from EV
and ACU
units.
• Check
physical
connec-
tions and
cable con-
dition, re-
place if
necessary.
Alarm name
Alarm type
SeaTalk fail
Safety Alarm
EEPROM
Safety Alarm
corruption
No Pilot
Safety Alarm
No
Safety Alarm
Compass
Rate Gyro
Safety Alarm
fault
Description
Action
Total
• Check
SeaTalk data
connec-
transmission
tions for
problem.
short or
open cir-
cuit.
• Check
system
for device
fault.
• Pilot drops
to standby
and alarm
times out
after 10
seconds.
A corruption
• Pilot drops
of critical
to standby
configuration
and alarm
data has
times out
occurred.
after 10
seconds.
The Pilot con-
• Check
troller has
Seatalk or
lost commu-
Seatalk
ng
nications with
bus wiring
the course
between
computer;
SPX
this alarm is
and Pilot
generated by
controller.
the Pilot con-
• Check that
troller.
the course
computer
is powered
up.
Compass
• Check
is not
connec-
connected.
tions and
compass
trans-
ducer.
The gyro
• Internal
sensor has
Gyro fail-
failed.
ure, inves-
tigate fault
and Con-
sult a Ray-
marine
Service
Agent.