E2S STExL1R008 Instruction Manual

E2S STExL1R008 Instruction Manual

Stexl1 series stexl2 series for use in flammable gas and dust atmospheres
Hide thumbs Also See for STExL1R008:

Advertisement

Quick Links

1) Warnings
 DO NOT OPEN WHEN AN EXPLOSIVE
ATMOSPHERE IS PRESENT
 POTENTIAL ELECTROSTATIC CHARGING
HAZARD
 ALL ENTRIES M20 X 1.5 - IF TEMPERATURE
EXCEEDS 70°C AT ENTRY OR 80°C AT
BRANCHING POINT USE SUITABLE RATED
CABLE AND CABLE GLANDS
2) Rating & Marking Information
All units have a rating label, which carries the following
important information:-
Input Voltage:
Low Impedance Units
Line Voltage Units
STExL1 Codes
:
Ex db IIC Gb T6 Ta -50°C to +55°C
Ex db IIC Gb T5 Ta -50°C to +70°C
Ex tb IIIC Db T95°C Ta -50°C to +70°C
STExL2 Codes
:
Ex db IIC Gb T6 Ta -50°C to +45°C
Ex db IIC Gb T5 Ta -50°C to +60°C
Ex db IIC Gb T4 Ta -50°C to +70°C
Ex tb IIIC Db T105°C Ta -50°C to +70°C
DEMKO 16 ATEX 1466X
Certificate No.
IECEx ULD 16.0017X
Epsilon x
Equipment Group and
Category:
CE Marking
Notified Body No.
_______________________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH
Document No.D199-00-101-IS
INSTRUCTION MANUAL (ATEX / IECEx)
For use in Flammable Gas and Dust Atmospheres
STExL1
8Ω or 16Ω
70Vline or 100V line
II 2G
II 2D
0518
Issue 1
13-07-16
STExL1 & STExL2 Loudspeakers
The units can be installed in locations with the following
conditions:
Area Classification Gas:
Zone 1
Zone 2
Gas Groupings:
Group IIA
Group IIB
Group IIC
Temperature Classification:
T1
T2
T3
T4
T5
T6
Area Classification Dust:
Zone 21
Zone 22
Dust Groupings:
Group IIIA
Group IIIB
Group IIIC
Ambient Temperature Range:
IP Rating: IP66 to EN/IEC60079-0 and EN/IEC60529
Equipment Category:
Equipment Protection Level:
Maximum Surface Temperature for Dust Applications:
95ºC
105ºC
sales@e-2-s.com
www.e-2-s.com
Sheet 1 of 4
STExL2
Explosive gas air mixture likely to occur in
normal operation.
Explosive gas air mixture not likely to occur
in normal operation, and if it does, it will
only exist for a short time.
Propane
Ethylene
Hydrogen and Acetylene
450ºC
300ºC
200ºC
135ºC
100ºC (up to 60ºC ambient for STExL2
only)
85ºC (up to 55ºC ambient for STExL1, up
to 45ºC ambient for STExL2 only)
Explosive dust air mixture likely to occur in
normal operation.
Explosive dust air mixture not likely to
occur in normal operation, and if it does, it
will only exist for a short time.
Combustible Flyings
Non-conductive Dust
Conductive Dust
-50°C to +70°C
2G/D
Gb, Gc, Db, Dc
(STExL1)
(STExL2)
Tel: +44 (0)208 743 8880
Fax: +44 (0)208 740 4200

Advertisement

loading

Summary of Contents for E2S STExL1R008

  • Page 1 INSTRUCTION MANUAL (ATEX / IECEx) STExL1 & STExL2 Loudspeakers For use in Flammable Gas and Dust Atmospheres STExL2 STExL1 The units can be installed in locations with the following 1) Warnings conditions:  DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT Area Classification Gas: ...
  • Page 2 3) Type Approval Standards The equipment carries an EC Type Examination Certificate and IECEx Certificate of Conformity, and have been certified to comply with the following standards: EN60079-0:2012+A11:2013 / IEC60079-0:2011 (Ed 6): Explosive Atmospheres - Equipment. General requirements Fig 1a. Fixing Location for Small Horn EN60079-1:2014 / IEC60079-1:2014 (Ed 7): Explosive Atmospheres - Equipment protection by flameproof enclosures "d"...
  • Page 3 IP 6X rating. Model No. Input Power Max. I/P (Watts) Volts The STEx loudspeaker range can be supplied with the STExL1R008 8Ohm 10.95 following types of adapters: STExL1R016 16Ohm 15.49 STExL1V070 70V Line M20 to ½” NPT...
  • Page 4 chamber the wires do not exert excess pressure on the connected to each terminal. If DC line monitoring is used cut terminal blocks. This is particularly important when using the link on the board (see Fig. 4). cables with large cross sectional areas such as 2.5mm². 14) Maintenance, Overhaul and Repair 12) 70V &...