Manual Mode
(Continued)
10. Change Flow and Speed settings while the IntelliFlo
The Set Flow and Set Speed settings can be changed on the fly while the pump is running. To
change the flow and speed settings, perform steps 3 through 8.
When "Set Flow" is used the pump will prime then ramp to the current flow rate.
It takes the pump about 60 seconds to two minutes to find a flow rate after it is primed. This is best seen
in Actual Speed status display.
While changing the Set Flow setting, the pump will re-prime after a value is changed.
While changing the Set Speed setting, the pump will immediately ramp to the current speed.
11. To stop the pump, press the Start/Stop button.
IntelliFlo Pump Control Panel Menu
Use the control panel menu to setup and configure IntelliFlo pump.
To access the menu features:
Ensure that the pump is stopped. Press the Menu button. Use the Up or Down arrow button to
scroll through the menu items. Use the Select button to select a menu item. Press the Enter
button to save a setting. Press the Escape button to move up a level from a selected menu item.
Menu Structure
The IntelliFlo pump menu structure is shown on the following page.
IntelliFlo Pump Control Panel with IntelliComm
®
IntelliTouch
Control System
The IntelliFlo pump control panel remains active when the pump is connected to an IntelliComm
communication center. For more information see page 29.
The IntelliFlo pump control panel is disabled when the pump is communicating with an IntelliTouch
control system. "DISPLAY NOT ACTIVE!" will be displayed. For more information see page 31.
®
VF Variable Flow Pump is running:
®