Sony SPP-935 Service Manual page 31

Table of Contents

Advertisement

• HAND MAIN BOARD U3 LSC433400FB (SYSTEM CONTROLLER)
Pin No.
Pin Name
1
RX ENABLE
2
LO BAT
3
OPEN
4 to 7
COL0 to COL3
8
IRQ/ROW0
9 to 13
ROW1 to ROW5
14
CRADLE DET
15
TX ENABLE
16
OPEN
17
VSS
18
RINGER
19
PLL EN
20
ATE IO
21
TX MUTE
22
OPEN
23
RX MUTE
24
INT COM LED
25
IN USE LED
26
BATT LOW LED
27
RDI
28
TDO
29
MISO
30
PLL DATA
31
PLL CLK
32
SS
33
TX DATA
34
RX DATA
35
TCAP
36
OSC2
37
OSC1
38
VDD
39, 40
OPEN
41
RESET
42
IRQ/ROW0
43
VPP
44
OPEN
I/O
O
RX system power supply on/off control signal output "L": power on
I
Battery level detect signal input from the LP2953IM (U11) "L": battery low level
O
Not used (open)
O
Key scan signal output to the key matrix
I
Key return signal input from the key matrix
I
Key return signal input from the key matrix
I
Detect signal input of the handset unit on cradle or off cradle "L": on cradle, "H": off cradle
O
TX system power supply on/off control signal output "L": power on
O
Not used (open)
Ground terminal
O
Ringer drive signal output terminal Normally: "L"
Chip enable signal output to the TB31202FN (U2)
O
When PLL EN goes from "L" to "H", it load data from PLL DATA
I/O
Communication in/out terminal with system controller (U3) on the base unit Normally: "L"
O
TX muting control signal output to the TA31103F (U7) "L": muting on
O
Not used (open)
O
RX muting control signal output to the TA31103F (U7) "L": muting on
O
INT COM LED drive signal output terminal "L": LED on
O
IN USE LED drive signal output terminal "L": LED on
O
BATT LOW LED drive signal output terminal "L": LED on
I
Not used (fixed at "L")
I
Not used (fixed at "L")
I
Not used (fixed at "L")
O
Serial data output to the TB31202FN (U2)
O
Serial data transfer clock signal output to the TB31202FN (U2)
I
Slave selection input terminal Fixed at "H" in this set
O
Transmit data output terminal
I
Receive data input terminal
I
Not used (fixed at "L")
I
System clock input terminal (4 MHz)
I
System clock input terminal (4 MHz)
Power supply terminal (+5V)
O
Not used (open)
System reset signal input from the reset signal generator (U11) "L": reset
I
For several hundreds msec. after the power supply rises, "L" is input, then it changes to "H"
I
External interrupt input terminal
Connected to power supply line (+5V)
O
Not used (open)
Function
– 44 –

Advertisement

Table of Contents
loading

Table of Contents