Wire And Cable Specifications - Panasonic VL-VN1500 Installation And Operating Instructions Manual

Video intercom system - door station
Table of Contents

Advertisement

Wire and cable specifications

Wiring run
Door station
Power supply unit
Power supply unit
Door station
Relay box
Note the following when selecting wiring
R For all wiring (except network wiring), use 2-conductor (solid copper) wiring with a PE
(polyethylene)-insulated PVC jacket.
Mid-capacitance, non-shielded wiring is recommended.
R A certified power supply wiring has to be used with this equipment. The relevant national installation
and/or equipment regulations shall be considered. A certified power supply wiring not lighter than
ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used.
R When connecting an electric lock, select a device that meets the following guidelines.
Electric lock connection terminal (Relay box: S1/S2):
– N/O dry closure contact
– 12 V AC/DC, less than 1 A
«
Switching hub
«
Door station
«
AC power source
«
Relay box
«
Electric lock
Specifications
Cat-5e or higher,
stranded, twisted pair,
straight
0.65 mm (22 AWG)
2 mm (12 AWG)
1.2 mm (17 AWG)
2 mm (12 AWG)
0.5 mm (24 AWG)
1.2 mm (17 AWG)
0.5 mm (24 AWG)
1.2 mm (17 AWG)
Installation
Max. length
100 m
approx. 10 m
approx. 20 m
No requirement
According to
specification of
connected device.
According to
specification of
connected device.
17