4. Installation
4.5 Wire and cable specifications
Wiring run
Lobby station
Power supply unit
Power supply unit
Lobby station
Note the following when selecting wiring
R For all wiring (except network wiring), use 2-conductor (solid copper) wiring with a PE (polyethylene)-insulated
PVC jacket.
Mid-capacitance, non-shielded wiring is recommended.
R A certified power supply wiring has to be used with this equipment. The relevant national installation and/or
equipment regulations shall be considered. A certified power supply wiring not lighter than ordinary polyvinyl
chloride flexible wiring according to IEC 60227 shall be used.
22
«
Switching hub
«
Lobby station
«
AC power source
Electric lock
«
Access controller
Open door sensor
Specifications
Cat-5e or higher, stranded,
twisted pair, straight
0.65 mm (22 AWG)
2 mm (12 AWG)
1.2 mm (17 AWG)
2 mm (12 AWG)
0.5 mm (24 AWG)
1.2 mm (17 AWG)
Max. length
100 m
approx. 10 m
approx. 20 m
No requirement
According to specification
of connected device.