This section describes the adjustment procedure that is
required when the safety related parts are replaced.
[Preparation]
. . . . . Required tools and measuring equipment
1. Signal generator
YPB/YPR signal generator
. . . . . 1080/60i (1125)
. . . . . 480/60i (525)
2. Electrostatic voltmeter: Singer ESH-27X or ESH-23X
or equivalent
3. Digital voltmeter
4. 200 kΩ variable resistor
5. 20 kΩ variable resistor
6. Ammeter
Component signal generator
BVM-D14H1U/D14H5U/D14H1E/D14H5E/D14H1A/D14H5A
Section 4
Safety Related Adjustments
: SMPTE 274M standard
: ITU601 (Refer to page 1-29)
BVM-D14H1U/D14H5U/D14H1E/D14H5E/D14H1A/D14H5A
. . . . . Set the INPUT CONFIGURATION menu
Set the INPUT CONFIGURATION menu of the SETUP
menu as shown below unless otherwise specified.
FORMAT ................................ YPBPR
SLOT NO ................................ 1
INPUT NO .............................. 1
SYNC MODE ......................... INT
APEARTURE VALUE .......... 100
CHANNEL NAME ................ PROG
COLOR TEMP ....................... STD
H PHASE ................................ 000
MARKER PHASE .................. 000
MARKER WIDTH ................. 000
SLOT No. 1
Y/G terminal
P
/B terminal
B
P
/R terminal
R
SYNC terminal
4-1