When replacing parts shown in the table below, the
following operational checks must be performed as a
safety precaution against X-ray emissions from the unit.
HV ADJ
HV Regulator
D board T501, IC501, RV501, R541,
Circuit
HV HOLD
D board T501, R510, R543, R547, R549,
DOWN Circuit
R552, R595, D515, D517, C540,
C542, C544, IC607, IC901
Beam Current
D board T501, R545, R546, R548, R550,
Protector Circuit
R596, R934, C535, C541,
IC605, IC607, IC901
Allow the unit to warm up for one minute prior to checking
the following conditions:
a
) HV Regulator Check
1) Input white cross hatch signal. (fH = 69 kHz)
2) CONT maximum and BRT center
3) Cut off Screen VR (G2).
4) Input voltage: 120 ± 2 VAC
5) Confirm that the voltage is within the voltage range
shown below.
Standard voltage: 26.9 KV ± 0.4 KV
6) When replacing components identified by
sure to recheck the High Voltage.
7) Verify the High Voltage as shown above (26.9 KV ±
0.4 KV) is within specification. If not, set H. SIZE data
at minimum (-127) and then adjust RV501 on "D" Board.
SECTION 3

SAFETY RELATED ADJUSTMENTS

Part Replaced (
)
RV501
Part Replaced (
)
R542, R544, R564, R567, R568,
C532, C534, C539, C553, C554,
C555, C556, C558, C561
, make
RV501
— 15 —
8) After adjusting the High Voltage within specification,
put the RV cover on RV501 as shown below and apply
sufficient amount of RTV around RV501.
b) HV Protector Circuit Check
1) Confirm that the voltage between cathode of D517 an
GND is more than 27.5 VDC.
2) Using an external DC Power supply, apply the voltage
shown below between cathode of D517 on "D" and GND,
and confirm that the HV Hold-Down circuit works. (Raster
disappears) Apply DC Voltage: Less than 35.8 VDC.
Check Condition
: 120 ± 2 VAC
• Input voltage
• Input signal
: (fH = 69 kHz), White Cross Hatch
• Controls
: CONT (max) & BRT (center)
: 179 ± 3.0 VDC
• B+ Voltage
c) Beam Protector Check (Software logic)
1) Using an external current source, apply < 1.55mA between
pin !¡ of FBT (T501) and GND, and confirm that the
raster fades out.
Check Condition
: 120 ± 2 VAC
• Input voltage
• Input signal
: (fH = 69 kHz), White Cross Hatch
• Controls
: CONT (max) & BRT (min)
d) B+ Voltage Check
1) Input white cross hatch (fH = 69 kHz) signal.
2) CONT (max) & BRT (center)
3) Input voltage: 120 ± 2 VAC
Note: Use NF power supply or make sure that
distortion factor is 3% or less.
4) Confirm that the voltage is within the voltage
range shown below.
Standard voltage: 179 ± 3.0 VDC