Checking Lubricant Level
1. Place the outboard in a vertical operating position. Allow up to 30 minutes
for the lubricant level to stabilize in the gear housing.
2. Remove the lubricant level plug. Verify the sealing washer is not adhered
to the bearing carrier. The lubricant should be level with the hole or slowly
leak from the hole.
IMPORTANT: Replace the sealing washers if damaged.
3. If lubricant is not visible at the lubricant level hole, remove the fill/drain
plug and add lubricant until it appears at the lubricant level hole.
4. Stop adding lubricant.
5. Allow a few minutes for the lubricant level to stabilize in the gearcase
before installing the lubricant level plug. Install the lubricant level plug.
6. Remove the lubricant tube and install the fill/drain plug and sealing
washer.
7. Tighten the plugs to the specified torque.
Description
Plugs
HEAVY DUTY 137 MM (5.4 IN.) DIAMETER GEARCASE
Gearcase Lubricant Capacity
Gearcase lubricant capacity is approximately 510 ml (17.2 fl oz).
Gearcase Lubricant Requirement
Mercury or Quicksilver High Performance Gear Lubricant.