Download Print this page
2gig Technologies pad1 Installing Manual

2gig Technologies pad1 Installing Manual

Indoor hd camera,image1

Advertisement

Quick Links

Quick Programming Guide
Control Panel Firmware Version 1.13
GETTING STARTED
To enter the control panel's System Configuration module to
program sensor zones and modify settings:
1.
At Home screen, tap logo in lower-right corner.
Enter:
Master Installer Code.
Tap:
System Configuration.
Or
2.
At Home screen:
Tap:
Security > Menu > Toolbox.
Enter:
Master Installer Code.
Tap: 
Installer Toolbox > System Configuration
To navigate through questions and options in the System Configuration
module:
Tap
to scroll between options on the active screen.
or
Tap orto move to the previous or next screen's question.
For step-by-step programming information, see the installation
instructions for the peripheral device or the control panel's
Installation and Programming Guide from dealer.2gig.com.
Q1 WIRELESS ZONE PROGRAMMING
(Q1) SELECT RF SENSOR # (01 to 48)
Select:
RF Sensor # (01 to 48)to select the desired zone option. Then
tap
Select:
RF Sensor # Typeto select type. Then tap
Select:
RF Sensor Equipment Codeto select code (see Equipment
Codes on page 4). Then tap
Enter:
RF Sensor # Serial Number (7 Digits) Enter the serial number or
place the control panel into learning mode by tapping Shift >
Learn and then trip the sensor to transmit its serial number to
the control panel.
RF Sensor # Equipment Ageto select (1) New or (2) Existing
Select:
Then tap
Select:
RF Sensor # Loop Numberto select (1) 1, (2) 2, or (3) 3:
1-Use Loop 1 for all 2GIG products (except as noted in loops
below)
2-Thin door/window contact using internal switch
3-Flood/freeze sensors. Then
Select:
RF Sensor # Dialer Delay (0 to 1)until desired
Construct:
RF Sensor # Voice Descriptor Tap Insert. Then tapto scroll
the available words or enter the 3-digit code associated with
the desired word. Tap Insert again before adding another word.
There is a five (5) word maximum. See Voice Descriptors on
page 4. Then tap
Select RF Sensor # Reports (0 to 1)to select (1) Enabled or (2)
Select:
Disabled. Then tap
Select:
Select RF Sensor # Supervised (0 to 1)to select (1) Enabled or
(2) Disabled. Then tap
Select:
Sensor Chime to select chime. Then tap
SUMMARY OF RF SENSOR # SCREEN
The Summary shows the settings for each sensor. Tap Edit Next to add the
next RF sensor, or tap Edit Current to reconfigure the current RF sensor. Tap
Q2 WIRED SENSOR PROGRAMMING
If no wired sensor programming is needed, tap Skip to go to Q3 Key Fob
Programming.
(Q2) ENTER WIRED SENSOR # (1 thru 2)
Select:
Sensor (Zone) Typeuntil desired
Select:
Equipment Age (New/Existing)until desired
Select:
Normal Stateuntil desired
(0) Not Used, (1) Normally Closed, (2) Normally Open, or (3)
Mixed with no EOL. Then tap
Select:
Dialer Delay (Enabled/Disabled)until desired
Construct:
RF Sensor # Voice Descriptor Tap Insert. Then tapto scroll the
available words or enter the 3-digit code associated with the
desired word. Tap Insert again before adding another word.
There is a five (5) word maximum. See Voice Descriptors on
page 4. Then tap
Select:
Sensor Reports (Enabled/Disabled)until desired
Select:
Sensor Chimeuntil desired option
SUMMARY OF WIRED SENSOR # SCREEN
The Summary shows the settings for each sensor. Tap Edit Next to add the
next wired sensor, or tap Edit Current to reconfigure the current wired sensor.
Tap Skip to move to Q3 Keyfob Programming.
Copyright © 2014 Linear LLC.
Download the Control Panel Installation Guide from
tap
option
option
option
option
option
For technical support in the USA and Canada:
2GIG dealer site at dealer.2gig.com, or email us at 2gigtechsupport@linearcorp.com.
For technical support outside of the USA and Canada, contact your regional distributor.
Q3 KEY FOB PROGRAMMING
If no key fob programming is needed, tap Skip to go to Q4 Keypad Programming.
(Q3) SELECT FOB # (1 to 8)
Fob <#> Used (0 to 1)to select (1) Disabled or (2) Enabled. Then tap
Select:
Fob <#> Equipment Code to select code (see Equipment Codes on
Select:
page 4). Then tap
Enter:
Fob <#> Serial Number (7-Digits) Enter the serial number manually (7
digits) or place the panel into learning mode by tapping Shift > Learn
and then tap the Armed Away button on the key fob until the LED
illuminates and the sensor transmits the serial number.
Select:
Fob # Equipment Age (0 to 1)to select (0) New or (1) Existing. Then
tap
Fob # Emergency Key (0 to 4)to select (0) Disabled, (1) Auxiliary
Select:
Alarm, (2) Audible Alarm, (3) Silent Panic, or (4) Fire. Then tap
Select:
Fob Can Disarm (Enabled/Disabled)until desired
Construct:
RF Sensor # Voice Descriptor Tap Insert. Then tapto scroll the
available words or enter the 3-digit code associated with the desired
word. Tap Insert again before adding another word. There is a five (5)
word maximum. See Voice Descriptors on page 4. Then tap
Fob # Arm No Delay (0 to 1)to select (0) Disabled or (1) Enabled.
Select:
Then tap
Fob # Key # Output (0 to 2)to select (0) Disabled, (1) Toggle
Select:
Output, or (2) Momentary Output. Then tap
SUMMARY OF FOB # SCREEN
The Summary shows the settings for each sensor. Tap Edit Next to add the next
keyfob, or tap Edit Current to reconfigure the current keyfob. Tap Skip to move to Q4
Keypad Programming.
Q4 KEYPAD PROGRAMMING
If no keypad programming is needed, tap Skip to go to Field Programming for
Communication.
(Q4) SELECT RF KEYPAD # (1 to 4)
Select:
Keypad RF Keypad # (1 to 4)to select desired keypad number. Then
tap
Select:
RF Keypad # Used (0 to 1)to select (0) Disabled or (1) Enabled.
Then tap
Select:
RF Keypad # Equipment
on page 4). Then tap
If using a Wireless Keypad (2GIG-PAD1)
Enter:
RF Keypad 1 Serial Number (7 Digits)
place the control panel into learning mode by tapping Shift > Learn
and then trip the sensor to transmit its serial number to the control
panel.
If using a Wireless Touch Screen Keypad (2GIG-TS1*)—*Not available in all
regions
Select:
RF Keypad # Keypad ID (Read-Only) Tap the Learn button. Then go to
the TS1 and tap the Pair WIth Panel button. When the learning
operation succeeds, tap OK on both the panel and TS1.
Select:
RF Keypad 1 Equipment Age (0 to
Existing. Then tap
Select:
RF Keypad # Emergency Keys (0 to
Enabled. Then tap
Construct:
RF Sensor # Voice Descriptor Tap Insert. Then tapto scroll the
available words or enter the 3-digit code associated with the desired
word. Tap Insert again before adding another word. There is a five (5)
word maximum. See Voice Descriptors on page 4. Then tap
SUMMARY OF RF KEYPAD # SCREEN
The Summary shows the settings for each sensor. Edit Next to add the next keypad,
Edit Current to reconfigure current keypad. Tap Skip to move to Field Programming
for Communication.
FIELD PROGRAMMING FOR COMMUNICATION
(Q13) SELECT TWO-WAY VOICE (0 TO 2)
Tap:
Go To. Then enter 13 to select a two-way voice option.
Select:
Two-Way Voice (0 to 2)to select (1) Stay On Line or (2) Stay On Line,
Including Fire and CO Alarms. Then tap
TO SETUP CELL PRIMARY: (Q8) SELECT DIALER (0 TO 1)
Tap:
Go To. Then enter 08 to select the dialer.
Dialer (0 to 1)to select (0) Disabled. Then tap
Select:
Tap:
Go To. Then enter 63 to select a phone fail detect option.
Select:
Phone Fail Detect (0 to 1)to select (0) Disabled. Then
TO SETUP POTS PRIMARY: (Q8) SELECT DIALER (0 TO 1)
option
Tap:
Go To. Then enter 08 to select the dialer.
Dialer (0 to 1)to select (1) Enabled. Then
Select:
Tap:
Go To. Then enter 63 to select phone fail detect.
Select:
Phone Fail Detect (0 to 1)to select (1) Enabled. Then
Tap:
Go To. Then enter 11 to enter the CS Phone Number.
Select:
CS #1 Phone Number (0-25 Digits) Enter the phone number. Then tap
Tap:
Go To. Then enter 12 to enter the CS Account Number.
Select:
CS #1 Account Number (4 Digits) Enter the account number. Then
855-2GIG-TECH (855-244-4832)
dealer.2gig.com.
Codeto select code (see Equipment Codes
1)to select (0) New or (1)
1)to select (0) Disabled or (1)
or visit the
option
Enter the serial number or
tap
tap
tap
tap
77-000010-001 Rev D

Advertisement

loading

Summary of Contents for 2gig Technologies pad1

  • Page 1 RF Keypad # Equipment below) on page 4). Then tap  2-Thin door/window contact using internal switch If using a Wireless Keypad (2GIG-PAD1) 3-Flood/freeze sensors. Then tap Enter: RF Keypad 1 Serial Number (7 Digits) Enter the serial number or Select: RF Sensor # Dialer Delay (0 to 1)until desired...
  • Page 2 Installing the Indoor HD Camera (2GIG-CAM-HD100)* *not available in all regions Control Panel Firmware Version 1.13 WIFI TO THE ON-SITE ROUTER (WPS) 1. If the on-site router supports WiFi Protected Setup (WPS), press the WPS button (A) until the routher enters WPS mode (the indicators will differ slightly from router to router).
  • Page 3 Z-Wave Quick Programming Control Panel Firmware Version 1.13 Download the Z-Wave Installation Guide from dealer.2gig.com. Always set the feature before programming any Z-Wave device: (Q79) SELECT Z-WAVE FEATURE (0 to 3) Tap: Go To. Then enter 79 to select a Z-Wave feature. Select: Select Z-Wave Feature (0 to 3)to select (0) Disabled and Hidden, (1) Disabled but Visible, (2) Enabled on Panel, Remote Access Disabled, or (3)
  • Page 4 Voice Descriptors Control Panel Firmware Version 1.13 ABORT EIGHTEEN KIDS RF JAM VOICE EIGHTY KITCHEN RIGHT WALL ACCESS ELECTRIC LAUNDRY ROOM WATER ALARM ELEVEN LEFT SAFE WEST EMERGENCY LEVEL SECOND WINDOW ANNOUNCEMENT ENTER LIBRARY SECURITY WIRELESS AREA ENTRANCE LIGHT SENSOR YARD ENTRY LIGHTS...

This manual is also suitable for:

Image1Cam-hd100