Shutting down the system

11.2 Recommissioning

See chapter "Settings and displays / Following an interruption to
the water supply"
12. Shutting down the system
f Isolate all poles of the appliance from the power supply.
f
f Drain the appliance (see chapter "Maintenance").
f

13. Troubleshooting

WARNING Electrocution
In order to check the appliance it must be connected to
the power supply.

13.1 Service mode

1
M1
1 Memory keys M1 and M2
2 Spanner symbol
The spanner symbol is displayed in the event of a fault.
f Activate customer service mode by pressing and holding
f
down both memory keys M1 and M2 for > 6 seconds.
f Disable customer service mode by briefly pressing one of the
f
three keys. Service mode is automatically terminated after
30 seconds of inactivity.
Fault displays
---
No display, there is no fault
ntc
Outlet sensor malfunction
ELE
Faulty PCB