1.7 SERVICE MENU
The service menu mode is used during servicing. It is configured as shown below.
The service menu can be run only when the RM-P2580 is used.
Press and hold the MENU button of the RM-P2580 for 3 seconds, then select CAMERA from the SETUP menu.
Press the SET button of the RM-P2580, then press the ENTER button 4 times within 4 seconds.
S
E
R
V
I
C
E
M
O
N
I
T
O
R
_
_
A
D
J
U
S
T
1
_
_
A
D
J
U
S
T
2
_
_
S
E
T
U
P
_
_
P
L
S
C
1
2
8
4
V
1
~~~~~~~~
~~~~~
Fig. 1-7(a)
MONITOR
ADJUST1
ADJUST2
SET UP
1-4
Fig. 1-7(a) shows the initial display of the SERVICE menu.
The menu items are selected with the pan/tilt control lever and pressing the SET button then enters the selection.
The menu items accompanied with "_ _" indicate that they have more menus in the lower hierarchy levels.
The setting of a menu item can be changed with the pan/tilt control lever. When the setting of an item is changed,
" * " is displayed between ">" and the item name. When the change is saved, " * " disappears.
ROM (IC14 on CPU board) part number and version are displayed.
.
0
0
M
O
N
I
T
O
R
I
R
I
S
A
v
D
a
t
a
I
R
I
S
P
k
D
a
t
a
I
R
I
S
T
O
T
A
L
D
a
t
a
D
C
I
R
I
S
L
E
N
S
A
G
C
G
a
i
n
W
.
B
A
L
R
-
B
D
a
t
a
W
.
B
A
L
M
g
-
G
D
a
t
a
R
G
a
i
n
B
G
a
i
n
Fig. 1-7(b)
S
E
R
V
I
C
E
A
D
J
U
S
T
>
F
S
C
1
2
F
H
1
2
Y
G
A
I
N
8
5
A
L
C
L
E
V
E
L
1
2
C
G
A
I
N
7
8
B
U
R
S
T
1
0
R
G
A
I
N
1
7
B
G
A
I
N
1
2
Fig. 1-7(c)
S
E
R
V
I
C
E
A
D
J
U
S
T
>
P
A
N
O
F
F
S
E
T
1
2
T
I
L
T
O
F
F
S
E
T
1
1
Fig. 1-7(d)
S
E
R
V
I
C
E
S
E
T
U
P
A
U
T
O
S
T
A
R
T
N
O
D
.
Z
O
O
M
M
A
X
X
2
B
R
A
K
E
O
N
Fig. 1-7(e)
This menu shows the camera status. The figures inside ( ) below indicate the
data display range. Pressing the MENU button returns to the initial display.
Average intensity level in the metering area. (0 - 752)
Peak intensity level in the metering area. (0 - 752)
1
7
5
Intensity level data in the metering area. This should be around 128
6
4
7
with ALC or around 115 with AGC when all adjustments are complete.
1
3
2
(0 - 1962)
9
2
DC iris lens voltage data. Indicates 255 at 5 V. (0 - 255)
0
AGC MODE data. Indicates 0 when the AGC MODE is OFF, 294 when
it is 10 dB, or 569 when it is 20 dB. (0 - 695)
–
7
1
5
–
6
7
1
Average vectorscope data when the data axis is (R-B), (Mg-G).
(-1024 - 1023)
3
4
7
7
5
1
R and B gain with respect to the G gain. (128 - 32640)
Adjustment menu.
1
See 2.4.5.
5
7
7
7
7
4
Adjustment menu.
2
See 2.4.5.
1
6
Menu for setup of the operation when 24 V AC is ON, without
using the remote control unit.
AUTO PAN : Auto pan operation.
R
M
A
L
A. PATROL : Auto patrol operation.
NORMAL
: No operation occurs.
Setup of the maximum magnification of the digital zoom.
Select from X1, X2 , X4 and X8.
Setup of brake ON and OFF.
Note
This menu is a hidden menu. Do not set the items to other settings
than those enclosed in
(except during the back-focus adjustment).