KDC-MP4032
[FM]
ROM correction version is displayed
key
(Display) ROM_R123
ROM_ERR_
ROM_R – – – (When not written in)
ROM_R ∗ ∗ ∗ (When data not matching)
[
]
AUDIO data initialization
key
(Display) AUD_INIT
[
]
Key pressed: Forced Power OFF data displayed.
key
While the forced power OFF data is displayed, press and
hold for 2 seconds or longer to clear the data.
(Display) POFF_ – – – (No Forced Power OFF)
system µ-com and panel communication error)
[
]
Key pressed: CD information display mode ON/OFF
key
While in CD information display mode, press and hold for
2 seconds or longer to clear all CD information.
∗ Please refer to the next table.
CD information display mode
I2C communication condition display
(Display) I2C_OK_ _
NG
[AM]
CD mechanism error log display
key
(switched by [
(Display) MCERR1: x x ↔ MCERR2: x x ↔
MCERR3: x x ↔ MCERR1: x x ↔
("– –" or the error code is displayed for "xx")
CD loading error log display (switched by [
(Display) LDERR1: x x ↔ LDERR2: x x ↔
LDERR1: x x ↔
(Number of times is displayed for "xx")
CD ejection error log display (switched by [
(Display) EJERR1: x x ↔ EJERR2: x x ↔
EJERR3: x x ↔ EJERR4: x x ↔
EJERR1: x x ↔
(Number of times is displayed for "xx")
12
TEST MODE
(When E2PROM is not installed)
SEC (Forced Power OFF because of
missing Security Code)
PNL (Forced Power OFF because of
] / [
] keys)
] / [
MAX 99 (times)
] / [
MAX 99 (times)
CD time code error count data display (missing counts)
(switched by [
(Display) CNT_LOSE ↔ CDDA_ _: xx ↔ CDROM_: xx ↔
CD time code error count data display (count not updated)
[FM]
(switched by [
(Display) CNT_STAY ↔ CDDA_ _: xx ↔ CDROM_: xx ↔
key

Security

1) How to enter the forced POWER ON mode

While "– – – –" is being displayed, while simultaneously
pressing [Q] key and [4] key, press [RESET] button, With
this, it is possible to turn the power on for 30 minutes only.

2) How to clear the programmable security code

1. While "– – – –" is being displayed, press [
seconds or longer while pressing the [AUTO] key. This
makes the "– – – –" display disappear.
2. Input "KCAR", using the remote controller.
Press [5] key of the remote controller twice (Input for "K")
and press [
Press [2] key of the remote controller 3 times (Input for "C")
and press [
Press [2] key of the remote controller once (Input for "A")
and press [
Press [7] key of the remote controller twice (Input for "R")
and press [
] keys)
3. The security is cleared and the unit enters STANDBY
source.
4. If wrong codes are input, "– – – –" will be displayed again.
] keys)
] / [
] keys)
CNT_LOSE ↔
(Number of times is displayed for "xx")
MAX 99 (times)
] / [
] keys)
CNT_STAY ↔
(Number of times is displayed for "xx")
MAX 99 (times)
] key.
] key.
] key.
] key.
] key for 3