Note: When sanding abrasive material (e.g. plaster,
etc.) we recommend connecting a suitable dust
extractor.
8. Cleaning, Maintenance
Emptying dust collection box (SR 10-23 Intec):
Open cleaning flap (8). Empty dust collection box
(7). Remove sanding dust filter (9) and knock off
dust stuck to filter or remove with brush.
During insertion: Ensure that sanding dust filter is
inserted into lateral guides.
Clean the machine regularly. This includes
vacuum cleaning the ventilation louvres on the
motor.
9. Accessories
Use only genuine Metabo accessories.
Use only accessories which fulfil the requirements
and specifications listed in these operating instruc-
tions.
For complete range of accessories, see
www.metabo.com or the main catalogue.
10. Repairs
Repairs to electrical tools must be carried out
by qualified electricians ONLY!
If you have Metabo electrical tools that require
repairs, please contact your Metabo service centre.
For addresses see www.metabo.com.
You can download spare parts lists from
www.metabo.com.

11. Environmental Protection

Observe national regulations on environmentally
compatible disposal and on the recycling of disused
machines, packaging and accessories.
Only for EU countries: Never dispose of
power tools in your household waste! In
accordance with European Guideline 2002/
96/EC on used electronic and electric equipment
and its implementation in national legal systems,
used power tools must be collected separately and
handed in for environmentally compatible recycling.

12. Technical Specifications

Explanatory notes on the information on page 3.
Changes due to technological progress reserved.
P
= Rated power consumption
1
P
= Power output
2
n
= Oscillating frequency at idle speed
0
n
= Oscillating frequency at rated load
1
C
= Dust collection box
A
= Sanding plate
S
= Oscillating circuit diameter
m
= Weight
Measured values determined in conformity with
EN 60745.
Machine in protection class II
~
Alternating current
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
Emission values
These values make it possible to assess the
emissions from the power tool and to compare
different power tools. Depending on the operating
conditions, the condition of the power tool or the
accessories, the actual load may be higher or lower.
For assessment purposes, please allow for breaks
and periods when the load is lower. Based on the
adjusted estimates, arrange protective measures
for the user e.g. organisational measures.
Vibration total value (vector sum of three directions)
determined in accordance with EN 60745:
a
= Vibration emission value
h
(Surface sanding)
K
= Unsafe (vibration)
h
Typical A-effective perceived sound levels:
L
= Sound pressure level
pA
L
= Acoustic power level
WA
K
, K
= Uncertainty
pA
WA
During operation the noise level can exceed
80 dB(A).
Wear ear protectors!