Connectors Layout Legend; C4.1 Modular; C4.1.1; End Limit Switch Connection - Electrolux WTCS90ERB Service Manual

Modular and compact rack-type dishwashers
Table of Contents

Advertisement

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
C3

CONNECTORS LAYOUT LEGEND

C4
END LIMIT SWITCH, ENERGY PEAK CONTROL AND EMERGENCY SWITCH CONNECTIONS
C4.1
MODULAR
The left and right side panels of the dishwasher have a connector "B" (Figure 9), closed with a plug "A"
(Figure 9).
Unscrew plug "A" (Figure 9) anticlockwise.

C4.1.1

END LIMIT SWITCH CONNECTION

Connect END LIMIT SWITCH (Outfeed side machine) between points 11 and 12 (Figure 10).

C4.1.2

EMERGENCY SWITCH CONNECTION

Connect EMERGENCY SWITCH OUT (Outfeed side machine) between points 7 and 8 (Figure 10) .
Connect EMERGENCY SWITCH IN (Infeed side machine) between points 7 and 8 (Figure 10).
A

Figure 9 Electrical connection

DOC. NO. 5956.573.05
F 3- F12
Main supply connector
F13-F16
Loads connector
F20-F28
Loads connector
F21-F31
Loads connector
F32-F37
Loads connector
F38-F40
Loads connector
x1
Temperature sensor connector
x2
Temperature sensor connector
x3
Inverter connector
x4
Temperature sensor connector
x5
Thermal protection, autostart, emergency switch - feed back inverter
x6
Board identification connector
x7
Air gap pressure sensor connector
x8
Gearmotor speed signal connector
x9
Thermal protection, autostart, emergency switch
x10
Door switch connector - user interface
B
EMERGENCY
SWITCH (7-8)
END LIMIT
SWITCH (11-12)

Figure 10 Detail of electrical connection