1. GENERIC FUNC.
Set default par.
2. Switch the machine off and then on again.
3. GENERIC FUNC.
Appl. type
Appl. direct.
Speed nr. 1
Wash time sp 1
Speed nr. 2
Wash time sp 2
Drain enable
Heat two comm.
Heating manage
Boiler load tank
Fahrenheit vis.
Rinse autostart
Max motor curr.
Nsf settings
4. RINSE MODULE
Boil. temp. start
Boiler temper.
Boiler temper warmup
Delta T stand-by
First boil. temp.
Duo temper.
Hist. duo temp.
Drain del. airgap
Duo heat. unrel.
5. WASH MODULE
Wash module
Tank temper.
Histeresys temp.
Condensing unit
Wash temp. ready
6. PREWASH MODULE
Prewash module
Standby level
Run level
7. DT MODULE
DT temper
DT type
8. Switch the machine off and then on again.
DOC. NO. 5956.573.05

Enter GENERIC FUNC. and set the following parameters.

Yes / 1
Sets all parameters to their default value.

Enter GENERIC FUNC. and set the following parameters.

8
Type of machine: Without Dt
10
Type of machine: With Dt

0
Rack feed direction: Left
1
Rack feed direction: Right

57
Indicates feed gear motor operation frequency at speed 1 [Hz].

63
Time from when the last rack releases the auto start lever until the wash
pumps stop when speed 1 [s] is set.
(Set to 73 if Rinse autostart

80
Indicates feed gear motor operation frequency at speed 2 [Hz].

45
Time from when the last rack releases the auto start lever until the wash
pumps stop when speed 2 [s] is set.
(Set to 52 if Rinse autostart

39
Enable draining and cleaning cycles.

0
Wash tank heating element management.

0
Machine heating power management.

0
The tank is filled by means of a dedicated solenoid valve.

Unit of measure used in displaying the temperatures; if set to "Yes" the
temperature is displayed in degrees Fahrenheit, otherwise in degrees
Celsius
0
Celsius visualization
1
Fahrenheit visualization

Indicates the type of rinse stage control.
0
Up to serial number 81100000
1
From serial number 81100001

see par. A4.8
Indicates the max. current deliverable to the gear motor by the inverter.

0
Duo and tank temperature standard setting.

Enter RINSE MODULE and set the following parameters.

92
Boiler temperature set point at start of rinse stage.

86
Boiler temperature set point.

86
Boiler warm-up temperature.

5
Boiler temperature decrease during standby.

59
First USA compact boiler temperature set point.

70
Tank temperature set point.

5
Tank hysteresis temperature.

32
Time from reaching level 0 (level in air trap) in the air gap, to stopping of
the rinse pump.

0
Enables activation of the DUO heating element even if the tank and
boiler heating elements are on.

Enter WASH MODULE and set the following parameters.

2
Type of wash module.

66
Tank temperature set point.

2
Tank hysteresis temperature.

0
Without CU
1
With CU

64
Wash tank "warmup end" temperature.

Enter PREWASH MODULE and set the following parameters.

0
Type of prewash module.

205
Indicates the max. level in prewash tank.

170
Indicates the max. prewash tank level when the prewash pumps are
working.

Enter DT MODULE and set the following parameters.

70
Drying tunnel temperature set point.

1
Indicates the type of DT installed.
PROG 010

= 0)

= 0)
P. 50 / 88