Electrolux WTCS90ERB Service Manual page 21

Modular and compact rack-type dishwashers
Table of Contents

Advertisement

Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
The WASH MODULE family contains the parameters that identify the wash module characteristics.
WASH MODULE
The WASH MODULE /  family parameters are described below:
Modular
Compact
parameter
parameter

Wash
module

Stanby
level (**)

Run max
level (**)

Drain max
lev. (**)

Max lev.
hister. (**)

Working
level (**)

Tank
temper.

Sanit.
temper.

Histesys
temp.

Max
Temp.
CU

Hist.
Temp.
CU
DOC. NO. 5956.573.05
MODULAR RACK TYPE
Family
Param
Parameter description
Nr.
eter
Nr.
3
0
Type of wash module
Modular Rack Type:
-0/ "1165" module from 1165 mm
-1/ "1490" module from 1490 mm.
Compact Rack Type:
- "2" Wash+Rinse module
3
1
Indicates the maximum level in the wash tank.
(**)
The filling stops when the water level reaches
this level.
3
2
The value for the maximum level is modified from
(**)
"Standby level" to "Run max level" during
washing phase in order to avoid water loss when
the pumps stop.
3
3
Meaninful only during "Drain and clean" cycle.
(**)
Indicates the maximum level during "Drain and
clean" cycle.
3
4
Indicates the hysteresis level relative to the
(**)
maximum level in the wash tank. It is related to
the "Standby level" to the "Run max level" and to
the "Drain max lev.".
3
5
Indicates the water level in the wash tank
(**)
enabling the wash tank heating elements and the
wash pumps operations.
3
7
Tank temperature set point.
3
8
Tank
sanitization phase (only on machines with
sanitization).
3
9
Hysteresis
temperature set point.
3
10
Max permissible temperature for the water
leaving the CU to enable heat pump operation. If
the
water
temperature, the machine continues to work
normally but the heat pump (if present) stops.
WARNING:
Do not modify this parameter unless
expressly required by the factory.
3
11
Max permissible temperature for the water
leaving the CU to enable heat pump operation: if
the temperature of the water leaving the CU falls
below "Max temp. CU - Hist. temp. CU", the
machine continues to work normally but the heat
pump (if present) stops.
WARNING:
Do not modify this parameter unless
expressly required by the factory.
temperature
set
point
during
temperature
relative
to
leaving
the
CU
exceeds
COMPACT RACK TYPE
Unit of
Min
measure
-
-
-
-
mmH2O
60
mmH2O
60
mmH2O
60
mmH2O
0
mmH2O
60
°C / °F
5/41
90/194
the
°C / °F
10/50
90/194
tank
°C / °F
0/0
50/90
°C / °F
1/34
90/194
this
°C / °F
1/2
50/90
Max
Factory
setting
[for
WTM165
(*)]
-
1490
-
2
400
205
400
170
400
190
80
30
400
90
66/151
75/167
2/4
50/122
20/46
P. 21 / 88