NEEDLE BAR HEIGHT

CORRECT SETTING
THE STANDARD DISTANCE BETWEEN THE UPPER EDGE OF NEEDLE EYE AND THE TIP OF
SHUTTLE HOOK SHOULD BE IN THE RANGE OF 2.9 MM - 3.5 MM WHEN THE TIP OF SHUTTLE
HOOK MEETS THE LEFT SIDE OF THE NEEDLE IN ASCENDING TRAVEL OF NEEDLE FROM ITS
LEFT AND LOWEST POSITION.
TO ADJUST
1.
REMOVE THE FACE PLATE. (SEE PAGE 4.)
2.
SET THE PATTERN SELECTOR DIAL AT "
NOTE:
FOR MODEL 2022 ...
3. REMOVE THE SHUTTLE RACE RING.
4.
TURN THE BALANCE WHEEL TOWARD YOU UNTIL TIP OF SHUTTLE HOOK MEETS THE
LEFT SIDE OF THE NEEDLE.
5.
LOOSEN THE NEEDLE BAR CONNECTING STUD SET SCREW.
6.
ADJUST THE HEIGHT OF THE NEEDLE BAR BY REMOVING THE NEEDLE BAR UPWARD
OR DOWNWARD WITHOUT TURNING IT.
7.
TIGHTEN THE SET SCREW.
8.
ATTACH THE SHUTTLE RACE RING.
9.
ATTACH THE FACE PLATE.
NEEDLE BAR CONNECTING
STUD SET SCREW
TIP OF SHUTTLE HOOK MEETS LEFT
SIDE OF NEEDLE.
MECHANICAL ADJUSTMENT
SET THE PATTERN SELECTOR DIAL AT "
SET THE WIDTH SELECTOR DIAL AT " 0 ".
NEEDLE BAR
15
". (STITCH LENGTH DIAL AT ANY POSITION.)
".
2.9 mm - 3.5 mm