Needle Bar Height - Janome CoverPro 1000CP Service Manual

Hide thumbs Also See for CoverPro 1000CP:
Table of Contents

Advertisement

(2)
(1)
(1)
(4)
(5)
(3)
7.8 - 8.2 mm (1000CP)
8.4 - 8.8 mm (900CP)
8

3. Needle Bar Height

The distance between the point of the left needle (Schmetz
ELx705, size 80/12) and the upper surface of the needle
plate should be 7.8 - 8.2 mm (1000CP) or 8.4 - 8.8 mm
(900CP) when the needle bar is at the highest position.
[1] Remove the face plate and front cover.
[2] Remove the setscrews (1) and lamp set plate (2).
[3] Replace the left needle with Schmetz ELx705, size 80/
12 needle (3).
[4] Turn the handwheel toward you to raise the needle bar
to the highest position.
[5] Loosen the setscrew (4) and move the needle bar (5)
up or down to adjust the distance at 8.0 mm (1000CP)
or 8.6 mm (900CP).
(Use the 5th and 6th steps from the left of the Gauge
795G-003 for 8.0mm and 8.6mm respectively).
NOTE:
Be sure not to rotate the needle bar when adjusting the
needle bar height.
[6] Tighten the setscrew (4) and attach the lamp set plate.
[7] Attach the face plate and front cover.
8 mm
8.6mm