Product Introduction; Technical Parameters - Bosch DKS968D Operating And Installation Manual

Table of Contents

Advertisement

Product Introduction

Technical Parameters

Product Standards
Safety Precautions
Product Model
Appearance
Rated Voltage
Input Power Motor
Light
Self Cleaning
Air Volume m
/min
3
Static Pressure Pa
Noise dB(A)
Net Weight (kg)
Dimension Length
mm
Width
Height
The product conforms to the following national
standards:
IEC 60335—1:2001 (Ed 5.0+ Appendix: 2004
+Appendix:2006) Household and similar electrical
appliances - safety - Part 1 General Requirements
IEC 60335—2—31:2006 (Ed 4.1) Household and
similar electrical appliances - safety - Part 2 - 31
Particular requirements for range hoods and other
cooking extractors
Risk of Carbon Monoxide Intoxication!
When the cooker hood is operated in exhaust air
mode simultaneously with a different burner which
also makes use of the same chimney, care must be
taken to ensure that there is an adequate supply of
fresh air which will be needed by the burner for
combustion.
Burn risk!
NEVER touch the lamp cover when the lamp is turned
on or off immediately as you may get burnt.
Fire risk!
Gas burners operated without cookware in position
produce a great amount of heat. The appliance or an
extractor hood fitted above it may be damaged or set on
fire. Only operate gas burners with cookware in position.
DKS968D
220-240V~50Hz
150W
2X20W
70W
14.5±1
≥300(max)
≤69 (sound power grade)
26.6
900
530
575
3

Advertisement