INITIAL FACTORY CONFIGURATION
Keys struck
Display
4,1
41
1
Personality selected as COUNTER/RATE
4,2
42
3
Reset Rate (A) Output(s) & Counter (B)
4,3
43
1
Count with Inhibit
4,4
44
1
Single edge counting (B)
4,5
45
1
Counter B Scale multiplier of 1.0
4,6
46
1
Counter B leading zero blanking and no decimal point
5,1
51
2
Outputs 1 & 2 assigned to Counter (B)
5,2
52
3
Output 1 terminates at Reset, Normal Phase
5,3
0000.10
Timed Output 1 Value of 0.1 Sec
5,4
54
3
Output 2 terminates at Reset, Normal Phase
5,5
0000.10
Timed Output 2 Value of 0.1 Sec
5,6
56
1
Counter (B), manual reset to zero
6,1
61
4
No Rate (A) right hand dummy zeros
6,2
62
1
Rate per Second
6,3
63
1
Rate (A) 0.5 Sec Minimum Update Time
6,4
64
4
Rate (A) Scale multiplier of 1
6,5
65
1
Rate (A) leading zero blanking, no decimal point
6,6
66
1
No functions except Reset enabled
3
01.0000
Scale Factor A (Rate) set to 1.0000
3
01.0000
Scale Factor B (Counter) set to 1.0000
1
000500
Preset 1 set to 500
2
001000
Preset 2 set to 1000
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Description
DUAL COUNTER FACTORY SETTINGS*
Keys struck
Display
4,1
41
2
Personality selected as DUAL COUNTER
4,2
42
3
Reset Counters A & B
4,3
43
1
Count with Inhibit
4,4
44
1
Single edge counting (A & B)
4,5
45
1
Counter B Scale multiplier of 1.0
4,6
46
1
Counter B leading zero blanking and no decimal point
5,1
51
2
Outputs 1 & 2 assigned to Counter B
5,2
52
3
Output 1 terminates at Reset, Normal Phase.
5,3
0000.10
Timed Output 1 Value of 0.1 Sec
5,4
54
3
Output 2 terminates at Reset, Normal Phase.
5,5
0000.10
Timed Output 2 Value of 0.1 Sec
5,6
56
1
Counter B, manual reset to zero
6,1
61
1
Counter A, manual reset to zero
6,4
64
1
Counter A scale multiplier of 1
6,5
65
1
Counter A leading zero blanking, no decimal point
6,6
66
1
No functions except Reset enabled
3
01.0000
Scale Factor A set to 1.0000
3
01.0000
Scale Factor B set to 1.0000
1
000500
Preset 1 set to 500
2
001000
Preset 2 set to 1000
* If [41 1] is changed to [41 2], then the factory settings are as shown.