Gemini 4100 Instruction Manual page 28

Astro-line series
Table of Contents

Advertisement

CODE 64 - COUNTER A SCALE MULTIPLIER
There are four Counter A scale multipliers that are available. They effectively
divide the internal Counter A Value by 1, 10, 100, and 1000 respectively, to yield
the displayed Counter A Value. Note: Use of a small scale multiplier in
conjunction with a small Scale Factor could cause the internal Counter A Value
to be exceeded before the 6-digit display value is exceeded.
[64 1] x1
[64 2] x0.1
[64 3] x0.01
[64 4] x0.001
CODE 65 - COUNTER A DECIMAL POINT & LEADING ZERO
BLANKING
There are six basic modes of decimal point placement for Counter A of the
Gemini. The decimal point is placed to the right of the display digit that
corresponds to the mode identifier. (The right most decimal point, digit 1, is
never turned on.) A "-" sign in front of the mode identifier will inhibit leading
zero blanking. The absence of a "-" sign will enable leading zero blanking.
[65 1]
0
[65 2]
0.0
[65 3]
0.0 0
LEADING ZERO
[65 4]
0.0 0 0
BLANKING
[65 5]
0.0 0 0 0
[65 6]
0.0 0 0 0 0
[65-1]
0 0 0 0 0 0
[65-2]
0 0 0 0 0.0
[65-3]
0 0 0 0.0 0
LEADING ZERO
[65-4]
0 0 0.0 0 0
BLANKING INHIBITED
[65-5]
0 0.0 0 0 0
[65-6]
0.0 0 0 0 0
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
CODE 66 - "OPERATOR ACCESSIBLE FUNCTIONS" MODES
The Gemini has six basic levels of "Operator Accessible Functions". Each of
these levels can be modified to enable or disable manual reset. When the "PGM.
DIS." (program disable) terminal is connected to "COMMON", access to all
functions is disabled except for those listed below which will remain enabled. All
of the function codes and parameters can be interrogated, regardless of the
"Operator Accessible Functions" mode selected.
A "-" sign in front of the mode identifier will disable the front panel Reset
button and the "RST." terminal.
Note: The front panel reset button can be independently disabled by using the
disable reset DIP switch.
[66 1] NO FUNCTIONS ENABLED EXCEPT RESET - In this mode, manual
reset is enabled, but none of the programming functions can be changed.
[66 2] PRESET PROGRAMMING AND RESET ENABLED - In this mode,
manual reset and the programming of the Preset Values are enabled.
[66 3] SCALE FACTOR PROGRAMMING AND RESET ENABLED - In this
mode, manual reset and the programming of the Scale Factor Values are enabled.
[66 4] SCALE FACTOR, PRESET PROGRAMMING AND RESET
ENABLED In this mode, manual reset and the programming of the Scale
Factor and Preset Values are enabled.
[66 5] PRESET, COUNTER LOAD PROGRAMMING, AND RESET
ENABLED - In this mode, manual reset and the programming of the Presets
and Counter Load Values are enabled.
[66 6] PRESET, SCALE FACTOR, COUNTER LOAD PROGRAMMING,
AND RESET ENABLED - In this mode, manual reset and the programming of
the Preset, Scale Factor and Counter Load Values are enabled.
[66 -1]
[66 -2]
[66 -3]
These modes are the same as above with
[66 -4]
the exception that reset is disabled.
[66 -5]
[66 -6]