Cleaning, Maintenance And Ordering Of Spare Parts - Scheppach HMS850 Translation From The Original Instructions

Planer/thicknesser
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
• Undo the clamp screws (A) by turning them
clockwise using the open-ended spanner (17)
supplied. Turn the knife block (23) so that the
latch (22) can be pulled out with the knife (21).
• Clean all the relevant parts and the knife slots in
the knife block (23).
• Fit the latch (22) with the new knife (21) and align
them with the side of the knife block.
• Place the blade adjustment block (15), as shown
in Figure 18, on the knife block. Make sure that
the knife (21) touches both sides of the blade
adjustment block (15).
• Tighten the clamp screws (A) using the openend-
ed spanner (17) supplied.
• Return the planing knife cover (12) to its original
position so that the knife (21) is covered.
m IMPORTANT!
Only use knives which are recommended by the
manufacturer for this equipment. If you use other
knives there is a risk of injuries due to lack of control.
Avoid over-tightening and the possibility of the
thread becoming detached. If the latch (22) or the
screws have worn out threads they must be immedi-
ately replaced.
10. Cleaning, maintenance and or-
dering of spare parts
General maintenance measures
Wipe chips and dust off the machine from time to
time using a cloth. In order to extend the service life
of the tool, oil the rotary parts once monthly.
Do not oil the motor.
When cleaning the plastic do not use corrosive
products.
m WARNING! Before cleaning~, adjustment~, main-
tenance~ or repair work, disconnect the power cord
from the main power supply!
10.1 Cleaning
• Keep all safety devices, air vents and the motor
housing free of dirt and dust as far as possible.
Wipe the equipment with a clean cloth or blow it
with compressed air at low pressure.
• We recommend that you clean the device immedi-
ately each time you have finished using it.
• Clean the equipment regularly with a moist cloth
and some soft soap. Do not use cleaning agents
or solvents; these could attack the plastic parts of
the equipment. Ensure that no water can seep into
the device. The ingress of water into an electric
tool increases the risk of an electric shock.
• The sawdust ejection and/or dust exhauster
should be cleaned at regular intervals.
• Never spray water on the machine!
10.2 Maintenance (Figure 1/15)
10.2.1 Machine
Lubricate the following parts periodically after
around 10 hours of service:
• Bearings for the feed/discharge rollers and anti-
kick claws (24)
• Bearings on the belt roller and pulley
• Grub screws to adjust the height of the thickness-
ing table (20)
Use only dry lubricant.
The feed table (13), planing table (14), thicknessing
table, feed/discharge rollers and anti-kick claws (24)
must be kept free of resin at all times. Soiled feed/
discharge rollers or anti-kick claws (24) must be
cleaned without delay. To prevent the motor over-
heating, the dust that accumulates in the ventilation
openings must be removed at regular intervals.
Improve the smooth running of the tables by apply-
ing lubricant at regular intervals.
10.2.2 Cutting tool
Resin must be cleaned off the knife (21), latch (22)
and knife block (23) at regular intervals. Clean these
components with an appropriate resin remover.
10.3 Ordering replacement parts:
Please quote the following data when ordering
replacement parts;
• Type of machine
• Article number of the machine
• Identification number of the machine
• Replacement part number of the part required
Repairs and works specified in these Instructions
may only be performed by qualified authorised staff.
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the
following parts are therefore also required for use as
consumables.
Wear parts:*
• motor drive belt
• carbon brushes
• planer blades
* Not necessarily included in the scope of delivery!
11. Storage
Store the equipment and accessories out of chil-
dren's reach in a dark and dry place at above
freezing temperature. The ideal storage tempera-
ture is between 5 and 30 °C.
Store the electric tool in its original packaging.
Cover the electrical tool in order to protect it from
dust and moisture.
Store the operating manual with the electrical tool.