Components; Receiver - Dometic FreshWell 2000 Operating Manual

Under-bench air conditioner
Hide thumbs Also See for FreshWell 2000:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Technical description
6.1

Components

The refrigerant circuit of the under-bench air conditioner consists of the fol-
lowing main components (fig. 1, page 3):
z Compressor (1)
The compressor draws in the refrigerant used and compresses it. This
raises the pressure and therefore the temperature of the refrigerant.
z Condenser (2)
The built-in liquefier works like a cooler or heat exchanger. The air flow-
ing past absorbs the heat and the hot refrigerant gas cools down and
becomes liquid.
z Evaporator (3)
The evaporators cool down and dehumidify the air flowing past them.
The refrigerant absorbs the heat and vaporises.
z Blower (4)
A blower distributes the cooled or heated air within the vehicle through
an air outlet unit.
6.2

Receiver

The receiver (fig. 2, page 3) contains the following control and display
elements:
No.
Explanation
1
Digital display
2
Red LED
3
Blue LED
4
Green LED
5
Yellow LED
In case of an alarm the display shows an error code to identify the fault:
Code
Explanation
E1
Air sensor or wire broken
E2
Evaporator tube sensor or wire broken
E7
Communication fault between PCB and PCB Display
12
Displays the room temperature.
The under-bench air conditioner is switched on.
The under-bench air conditioner is in night mode.
The compressor is working.
Constantly lit: the timer mode is switched on
Flashing: the ventilation is temporarily suspended
FreshWell2000