Electrical Safety; Start-Up Instructions - Jacuzzi J-315 Installation Manual And Use & Maintenance

J-300 series
Hide thumbs Also See for J-315:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
I
Do not use a spa immediately following strenuous exercise.
I
Be very careful when getting in an out of the spa. All of the sur-
faces are slippery when wet.
I
The spa is not intended for use in public places; always check
for any restrictions and/or regulations concerning the installation
and use of the apparatus in the area chosen.

Electrical safety

®
The MaxiJacuzzi
are safe products, manufactured in compli-
ance with standards
60335-1: 2002, 60335-2-60: 2003, 60825-
1: 1994+A1+A2, EN 55014-2, CISPR 22 CLASS B, EN
61000-3-2, EN 6100-3-3
ensure user safety.
I
Installation must be performed by qualified personnel who
ensure compliance with current national regulations and who
are also authorized to issue a certificate of compliance with
proper installation procedures.
It is the responsibility of the installer to select ma-
terials based on their intended use, to carry out
work properly, to check the condition of the system
that the unit will be connected to and that it en-
sures safety of use also concerning maintenance
work and the possibility to examine the system.
I
®
The MaxiJacuzzi
are class "I" appliances and therefore they
must be permanently connected, without any intermediate
connections, to the electrical system and to the protection
system (earth system).
The electrical system of the building must be pro-
vided with a 0.03A differential switch and with an
efficient protection (earth) circuit.
Check for proper operation of the differential switch
by pressing the TEST button, which should trip.
Parts incorporating electrical components, except
remote control devices, must be located or fixed
so that they cannot fall into the spa.
Live components and equipment must be out of
reach of individuals in the spa.
I
For connection to the electrical mains, it is necessary to install
an omnipolar cut-off switch as per the values indicated in the
chapter "Electrical characteristics., which is to be located in an
area which is compliant with safety instructions and which can-
not be reached by the users who are using the MaxiJacuzzi
It is mandatory to comply with this instruction. Any other proce-
dure is prohibited.
I
The installation of electrical devices and equipment (sockets,
switches, etc.) near the MaxiJacuzzi
with legal standards and regulations in the country where the
®
MaxiJacuzzi
is installed.
and tested during production to
®
must be in compliance
I
The disconnection devices must be installed in the power
supply network according to the installation instructions.
I
For the equipotential connection as required by specific
national standards, the installer must use the terminal provided
(standard EN 60335.2.60) in the electrical box, and marked
with the symbol
be established for all metallic masses surrounding the spa, for
example water and gas pipes, metallic platforms, and so on.
Refer to the pre-installation information sheet for in-
structions and electrical input of the various models.

Start-up instructions

Read each step in its entirety before proceeding with
that step.
I
Remove any dirt from the spa. Although the spa shell has been pol-
ished at the factory, you may want to treat it with a specially formulated s-
pa cleaner and wax available from your dealer prior to filling the first time.
I
Filling the spa
Remove the filter cover, then remove both filter cartridges as out-
lined in section "Cleaning The Filters".
Position the end of the hose inside the filter connection and fill
the spa until the level of water covers all of the nozzles, without
however reaching the headrest.
Do not overfill your spa.
N.B.: If your water is extremely hard, it is preferable to fill
halfway with hard water and the rest of the way with softened
water.
Always refill the spa through both filter fittings to purge trapped
air from pump intakes. Failure to do so may cause air to be
trapped in either pump 1 or the circulation pump's intake, pre-
venting the pumps from circulating water.
After filling, make sure both filters are installed properly before
applying power to the spa. (refer to sec.) "Cleaning the filters").
I
Checks
Open the cabinet access panel and check all pump fittings to
make sure they are tight. Loosening can occur during shipping
and handling.
I
Turning on power
Turn on power to spa at the home's circuit breaker: the heater and
circulation pump automatically activate. The water temperature LED
®
.
flash on the control panel and the messages "COL" or "ICE" appear.
Note: "COL" and "ICE" will only appear when the spa is in Econo-
my mode.
I
Start-up
Activating the pump(s)
I
Addition of chemical additives at first start-up
Please refer to the Jacuzzi system water treatment guide and rela-
22
.
In particular, an equipotential condition must

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

J-335J-355J-345J-375

Table of Contents