1. Grasp center pillow insert (A) with finger tips and gently pry
outward from pillow base (C).
2. Use a standard screwdriver to loosen and remove mounting
bolts (B) from pillow base.
3. Assemble in reverse order after cleaning, taking care not to
over tighten.
Maintaining the cover
Using the insulating spa cover anytime the spa is not in use will
significantly reduce your operating costs, heat-up time and main-
tenance requirements.
To prolong the life of the cover, handle it with care and clean it
regularly using mild soap and water.
N.B.: Never allow anyone to stand or sit on the cover.
Panel maintenance
The panels do not require any special maintenance. To clean them,
just wipe them with a clean cloth and a neutral detergent solution.
ATTENTION: do not direct jets of water against the panels,
since electro-mechanical parts are located behind them.

Winterizing

I
Your Jacuzzi
®
Premium spa is designed to automatically protect
itself against freezing when operating properly.
I D
uring periods of severe freezing temperatures, you should
check periodically to be certain that the electrical supply to the s-
pa has not been interrupted.
I
In extreme cold weather, choose the F3 "Standard" skim-
ming/heating mode to prevent freezing.
I
If you do not intend to use your spa, or if there is a prolonged
power outage during periods of severe freezing temperatures, it is
important that all water be removed from the spa and equipment
to protect against damage from freezing.
For expert winterization of your spa, contact your author-
ized dealer.
In emergency situations, damage can be minimized by taking the
following steps:
- Disconnect the spa from the electric mains.
- Follow the directions for draining the spa.
- Get the water out of the recessed seating areas and footwell.
- Position the massage switch in position A (combo).
B
C
A
- Open the valve of the cascade with the correct knob.
- Remove the side panels and locate the drain plugs of the
pumps. Remove these plugs to allow the water to drain out of
the pumps and heater.
Use a vacuum or other means to keep the water from flood-
ing the system compartment.
- Replace the drain plugs.
- Loosen the hose clamp on the circulation pump intake behind the
electrical box, pull the hose off and drain it. Reinstall hose and clamp.
- Re-install cabinet panels and cover spa with the insulating cover.

Restarting your spa in cold weather

If you want to start up your spa after it has sat empty for a time
in freezing temperatures, check whether the water remaining in
certain sections of the piping is still frozen: this situation may
block water flow preventing the spa from operating properly and
possibly damaging the equipment. We recommend you consult
your dealer for guidance before attempting to restart your s-
pa under these conditions.
CLEARRAY™ Water Purification System
CLEARRAY Water Purification System is exclusive technology
utilizing natural ultraviolet technology to eliminate waterborne
bacteria, viruses, and algae in portable spas. The ultraviolet light
otherwise know as UV-C or germicidal light inactivates the mi-
croorganisms disrupting the DNA so that it cannot reproduce and
is considered lifeless. CLEARRAY is plumbed in-line with your
filtration system. After the water is drawn from the pump, filter,
and heater it is then directed though the CLEARRAY system. Wa-
ter passes through an ultraviolet light energy that treats and
disinfects the water. The water is then pumped back into the s-
pa giving you crystal clear water instantly. The system has a bal-
last that is the power supply for the purification system; it has
two LED indicator lights the green indicating incoming power
flow and the red indicating the system is properly working.
CLEARRAY is standard for all models.
Note: The CLEARRAY System only runs when the circulation
pump is running and shuts off when either jets pump is manu-
ally activated during spa use. The system will remain off for 5
minutes after both jets pumps time out or are manually turned
off, then resume operations if the circulation pump is pro-
grammed to run.
After a year the lamp bulb must be replaced. If the UV timer has
been programmed correctly a message will appear on the LED
display when the time allotted has expired. In order to clear the
"blb" message a new UV lamp bulb needs to be installed and the
timer must be reset.