Sync; Sdi Through; Input Signal Display - Panasonic TH-50VX100E Operating Instructions Manual

High definition custom home theater plasma display
Hide thumbs Also See for TH-50VX100E:
Table of Contents

Advertisement

Setup for Input Signals

Sync

Select Signal from the "Setup" menu during RGB input signal.
Signal
Sync
XGA Mode
1024 ×768
Setting RGB sync signal:
Confirm that the input is set to RGB input (this setting is valid only for RGB input signal).
Auto: The H and V sync or synchronized signal are automatically selected. If both input, it is selected the H and
V sync.
on G: Uses a synchronized signal on the Video G signal, which is input from the G connector.
VBS: Uses a synchronized signal of Composite Sync input, which is input from the HD connector.

SDI Through

Set the active through function of the Dual Link HD-SDI Terminal Board (TY-FB11DHD).
Note:
Settings can only be performed for this menu when a slot mounted with a Dual Link HD-SDI Terminal Board
(TY-FB11DHD) is selected.
Signal
SDI Through

Input signal display

Displays the frequency and the type of the current input signal.
This display is valid only for Component / RGB / PC and Digital input signal.
Display range:
Horizontal 15 - 110 kHz
Vertical 48 - 120 Hz
The dot clock frequency is displayed during digital signal input.
40
[ RGB ]
Auto
Auto
[ Digital ]
Off
Off
On
On:
Enables active through.
Off:
Disables active through.
change
2
select
1
on G
VBS
change
2
select
1
H-Freq.
33.7 kHz
V-Freq.
60.0 Hz
Signal Format
1125(1080)/60i
H-Freq.
33.7 kHz
V-Freq.
60.0 Hz
Dot Clock Freq.
108.0 MHz
Signal Format
1125(1080)/60i