Siemens SIMATIC PCS 7 Service Manual page 138

Process control system
Hide thumbs Also See for SIMATIC PCS 7:
Table of Contents

Advertisement

Failure, replacement and return
9.1 Failure, replacement and return - guide to documentation
Scenario
Automation systems
Failure of a CPU in a redundant
AS
Failure of synchronization be‐
tween the CPUs in a redundant
AS
Communication
Failure and malfunction:
SCALANCE X-400
Failure and malfunction:
SCALANCE X-300
Failure and malfunction:
SCALANCE X-200
Disrupted network connections
Faults on PROFIBUS DP
Faults on PROFIBUS DP
Faults on PROFINET
Operator control and monitoring stations
Failure of a redundant OS server
Switchover response of OS cli‐
ents in the event of an OS server
failure
138
Information can be found in ...
Configuration manual
Process Control System PCS 7; Fault-Tol‐
erant Process Control Systems
Configuration manual
Process Control System PCS 7; Fault-Tol‐
erant Process Control Systems
Operating instructions
SIMATIC NET;
Industrial Ethernet Switches SCALANCE
X-400
Operating instructions
SIMATIC NET;
Industrial Ethernet Switches SCALANCE
X-300
Commissioning manual
SIMATIC NET;
Industrial Ethernet
SCALANCE X-100 and SCALANCE X-200
product line
Configuration manual
PCS 7 Process Con‐
trol System; Fault-Tolerant Process Con‐
trol Systems
SIMATIC; Diagnostic Repeater for
Manual
PROFIBUS DP
SIMATIC; Bus Link;
Operating instructions
Extended fieldbus diagnostics in PROFI‐
BUS PA
SIMATIC; PROFINET System De‐
Manual
scription
PCS 7 Process Con‐
Configuration manual
trol System; Fault-Tolerant Process Con‐
trol Systems
PCS 7 Process Con‐
Configuration manual
trol System; Fault-Tolerant Process Con‐
trol Systems
Section ...
● Failure of the Master CPU
● Failure of a Fiber-Optic Cable
● Installation and Commissioning
Installation and removal
Displaying LEDs
Replacing the C-PLUG
● Installation and Commissioning
Installation and removal
Displaying LEDs
● Installation and Maintenance
● Configuration / Diagnostics via Remote
Mechanisms
● SCALANCE X2<...> Display
● Failure, Failover and Restarting of
Redundant OS Servers
Disrupted network connection to the
OS partner server
Disrupted Network Connection
Between the OS Client and the OS
Server
Disrupted Network Connection
Between the OS and AS
● Commissioning
● Diagnostics
● Installation and removal
● Commissioning
● Displaying LEDs
● Diagnostics
● Diagnostics for PROFINET IO
● Diagnostics for PROFINET CBA
● Failure of a redundant OS server
● Switchover response of OS clients in
the event of an OS server failure
Service Support and Diagnostics (V8.2)
Service Manual, 03/2016, A5E36200111-AA