TO JUNCTION
6V DC
BOX (120V)
SUPPLY
FLAME
MODULATION
Figure 8.2 Intellifire Pilot Ignition (IPI) Wiring Diagram
Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall mounted switch for use
with a fan (See Figure 8.3 ):
• The power supply for the appliance must be brought into
a switch box.
• The power can then be supplied from the switch box to the
appliance using a minimum of 14-3 with ground wire.
• At the switch box connect the black (hot) wire and red
(switch leg) wire to the wall switch as shown.
• At the appliance connect the black (hot), white (neutral)
and green (ground) wires to the junction box as shown.
• Add a 1/4 in. insulated female connector to the red (switch
leg) wire, route it through the knockout in the face of the
junction box, and connect to the top fan switch connector
(1/4 in. male) as shown.
46
Heatilator • NNXT4236IF-B, NNXT4236ILF-B, NNXT3933IF-B, NNXT3933ILF-B Installation Manual • 2384-980 Rev. J • 6/17
FLAME
SENSE
CONTROL MODULE
I
S
IGNITER
3 PRONG 120VAC
AUX200 MODULE
BATTERY PACK
6V DC
Minimum 14-3 AWG
with Ground
Junction Box
Red
Figure 8.3 Junction Box Wired to Wall Switch or BC10
RC200 12V DC
(A23 X 1)
TO JUNCTION
BOX 120VAC
Red
Black
Black
White
White
Green
Green
Switch Box
Supply
Knockout
Switch
Power
Wires